Kärcher Tornado NT 361 Eco Manual página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Switch Power Filter Clean off
Setting of the slide (1) - upwards
Note:
♦ When vacuuming wet dirt with the
upholstery or the crevice nozzle or if
predominantly water is to be
vacuumed out of a container it is
adviseable to turn the - Power Filter
Clean – operation off. .
♦ The appliance turns itself
automatically off when the max.
liquid level has been reached.
♦ Switch the appliance off and empty
the container.
♦ Clean and dry the flat pleat filter and
the electrodes as well as the
container after finishing wet
vacuuming jobs.
NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE
CARE AND MAINTENANCE
♦ Always pull out the mains plug when
working on the suction machine.
Replace the flat pleat filter or the
exhaust air filter
¾
Open the filter cover (1)
¾
Replace the flat pleat filter (2) or
the exhaust air filter (3)
¾
Close the filter cover, it must engage
audibly
Clean electrodes
¾
Unlock and remove the suction head
¾
Clean electrodes
¾
Replace the suction head and lock it
in place
FAULT INSTRUCTIONS
The suction turbine does not run
• Check the cable, plug, fuse and
socket.
• Switch on the machine.
The suction turbine switches off
• Empty the container.
The suction turbine does not restart
following emptying of the container
• Switch the appliance off and wait
for 5 s, switch it on again after 5 s.
• Clean the electrodes as well as the
space between them.
The suction power decreases
• Remove the parts clogging up the
suction nozzle, the suction tube, the
Power Filter Clean handle, the
suction hose or the flat pleat filter.
• Change the paper filter bag.
• Actuate the filter cleaner: Power
Filter Clean several times at the
handle.
• Engage the filter cover properly.
• Replace the flat pleat filter.
Dust ejects when sucking
• Check the proper mounting position
of the flat pleat filter.
• Replace the flat pleat filter.
The (wet-vacuuming) automatic
switch-off does not respond
• Clean the electrodes as well as the
space between them.
• Constantly check the filling level for
an electrical non-conductive liquid.
Power Filter Clean switches
regularly
• Loosen suction nozzle or end of
hose when caught on vacuumed
object.
• Stop continuous vacuuming from the
liquid container and turn
the operation - Power Filter Clean –
off (see section Wet-Vacuuming).
• Remove the parts clogging up the
suction nozzle, the suction tube, the
Power Filter Clean handle, the
suction hose or the flat pleat filter.
• Replace the flat pleat filter.