5. Any openings in the wall behind the range and in the
floor under the range must be sealed.
6. When there is less than a 12² clearance between
combustible material and the back edge of the range,
(above the cooking surface) Jenn-Air Stub Back or
High Shelf Backguard must be installed. These parts
must be ordered separately, except for the PRG3010
which comes equipped with a Low Back. Figure 3A
F
G
D
H
C
Low Back
0² Clearance
A
FIGURE 3A
TABLE 2
DIMENSIONS
PRG4810
PRG3610
PRG3010
High Shelf
36² Min. To
Combustibles
E
B
A
B
27-7/16²
44-11/16²
27-7/16²
44-11/16²
26-3/4²
44-1/4²
and Figure 3B indicate the space required for each
type of backguard.
7. Always keep the appliance area clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.
8. Do not obstruct the flow of combustion and ventilation
air to the unit.
1-1/2²
C
D
12²
21-1/4²
29-15/16²
12²
21-1/4²
29-15/16²
9²
21-1/4²
29-15/16²
6
12² Min. To Combustibles
Without Backguard
Island Trim
0² Clearance
FIGURE 3B
E
F
G
28-3/16²
10²
28-3/16²
10²
28-3/16²
9-3/8²
36² Min. To
Combustibles
H
2-1/2²
2-1/2²
1-3/4²