Maximum Operating Pressure - Palazzetti MUTIFIRE IDRO NT Serie Uso Y Funciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.9.1
Description of water circuit (fig. 5.9)
A) Thermal discharge valve connected to a remote
bulb sensor
B) Water inlet (aqueduct) for safety heat sink and load
system (G1/2' M)
C) Safety heat sink outlet to be connected to a waste
tube (G1/2' M)
D) Hot water return to the system (G1')
E) Water flow from the system (G1')
F)
Anti-condensation valve
G) Safety valve (G3/4" F)
H) Circulator
I)
Tap for boiler discharge
J)
Supply tap.
K) Closed expansion vessel
L)
Automatic release valve
M) Pressure gauge
N) Sleeves G1/2" F for the connection of probe pockets
O) Door microswitch
P) Flue temperature sensor
Q) Ash drawer microswich
5.9.2 Water connections (fig. 5.9)
Connect stove to the heating system through
the flow and return tubes (D-E).
Collegare il circuito idraulico dell'acquedotto al
tubo di sicurezza (B).
Connect the water circuit of the aqueduct to
the safety tube (B)
Prepare a waste tube, of appropriate diameter,
to which to connect the discharge of the safety
valve (G) and the discharge tube of the safety
heat sink (C).
After making the water connections, it is necessary
to proceed to load the boiler (tap J) and the related
vent (L), checking the pressure (1-1.2 bar cold) via
the pressure gauge on the side of the stove (M).
If necessary, make sure that the closed expansion
vessel preload (K) is correct.
MAXIMUM OPERATING PRESSURE: 2.5 bar
It is good practice to proceed with washing the
system before commissioning the operational
system with its final load.
To ensure permanent high efficiency and long life
of the product, a water softener is recommended
to ensure that the water hardness of the system
is less than 25-27 French degrees and to add
anti-algae treatment to the system's water as
necessary.
32
M
N
O
00 477 6120 - 20/03/2019
L
Q
H
I
J
O
G
I
K
P
A
B
C
E
D
F
358
fig. 5.9