6.1.2.1 Cleaning the fumes circuit:
-
Open the door of the stove and extract from their seating the two upper magnofix panels (fig. 6.1).
-
On the inspection chamber of the fumes circuit, unscrew the screws of the front plug (fig. 6.2) and
extract the magnofix fumes deflector; check the conditions of the seal and replace it if necessary.
Extract the two catalyser elements and clean them using a vacuum cleaner and a dry brush (fig. 6.3).
-
-
From the top inspection chamber, gently lift the turbolators immersed in the exchange tubes and
extract the metal plug that locks them in position (fig. 6.4).
-
Extract the turbolators from below and clean the exchange tubes (fig. 6.4).
-
Repeat the above operations in reverse order, reassembling the various elements in their seatings.
fig. 6.1
fig. 6.3
00 477 6120 - 20/03/2019
fig. 6.2
fig. 6.4