5.6 LEVELLING THE STOVE
The stove must be levelled by adjusting the feet (where featured), then checked using a spirit level (Fig. 5.10).
A B = Spirit level
5.7 SYSTEM CONNECTIONS

5.7.1 Electrical connection

The stove is connected to the electrical system simply using the plug supplied.
The electrical connection (plug) must be easily accessible when the stove is installed.
If the power cord is damaged it must be replaced by the technical service or a qualified technician, to prevent
any kind of risk.
5.7.1.1 Earth
The system must be earthed and fitted with a residual current circuit-breaker in accordance with legislation in
force (Fig. 5.11).
The flue must have its own earth connection.
5.7.2 Connection to an external timer thermostat
The stove can be connected to an external timer thermostat that switches the stove on or off according to the
set temperature.
For electrical connection, refer to the wiring diagram in the technical specifications.
5.8 IMPROVING THE COMBUSTION
A good combustion depends on several factors (type of installation, operation and maintenance conditions, type
of pellet etc ..)
During the first burning, it is possible to optimize the combustion of the stove.
If at the end of combustion in the brazier are many waste, it is advisable to change the combustion configurations
(increasing the value) to find the most satisfactory solution.
Refer to section "improving the combustion" of the user manual.
6
MAINTENANCE
6.1 MAINTENANCE
The stove may only be maintained by an authorised technical service centre.
Prior to effecting any maintenance operation, adopt the following precautions:
• Make sure that the stove is completely cold.
• Make sure that the ashes have gone out completely.
• Use the personal protective equipment specified in Directive 89/391/EEC.
• Make sure the mains power is off at the master power switch.
• Ensure that the power supply cannot be restored accidentally. Remove the power plug from the socket.
• Always use proper tools.
• Once maintenance or repair activities are completed, reinstall all the protections and reactivate all the safety devices prior
24/136
fig. 5.10
00 477 5811 - 05/04/2019 - PN - Italy
fig. 5.11