7
SIDE LOADING WITH CHAIN TRANSFER
ALIMENTACION LATERAL CON UNA TRANSFERENCIA DE CADENA
(DIF F U S E S H O WN) WITH A U XILIA R Y
(MÓDULO DE ZONA EZLOGIC
CONTROLS REQUIRED:
When side loading an intermediate zone with a chain transfer, the zone preceding the transfer zone and the transfer zone (13 and 14) must be monitored and/or
controlled. The transfer zone (14) must be clear before product may be transferred onto the conveyor. A zone stop signal to (13) will prevent any upstream
loads from entering the transfer area. A zone stop signal to (14) will prevent the load being transferred from advancing until the transfer is fully retracted.
Other controls are required for the transfer and the feed line.
CONTROLES REQUERIDOS:
Cuando una sección intermedia con una transferencia de cadena es cargada por uno de sus lados, las zonas precedentes y posteriores a la zona de transferencia (13 y
15) deben ser monitoreadas y/o controladas. La zona de transferencia (14) debe estar libre antes de que el producto pueda ser transferido al transportador. Una seĖal de
paro de zona en (13) evitará la entrada de cualquier carga al área de transferencia. Una seĖal de paro de zona en (14) evitará que la carga siendo transferida avance
hasta que la transferencia esté en posición correcta.
Se requieren otros controles para la línea de transferencia y de alimentación.
20
EZLOGIC® ZONE CONTROLLER
I/O MODULE
®
(MÓDULO DE ZONA EZLOGIC
CON MÓDULO
AUXILIAR I/O [DIF U S O MOS T R A DO]
ZONE
ZONE
12
FLOW
EZLOGIC® ZONE
CONTROLLER (DIF F U S E S H O WN)
®
) [DIF U S O MOS T R A DO]
ZONE
ZONE
13
14
15
ZONE STOP SIGNAL
(SENAL DE ZONA DE PARADA)
ZONE
16
CHAIN TRANSFER
(TRANSFERENCIA DE CADENA)