4.13 Resistance Test
1) Insert black probe to COM jack, insert red probe to INPUT jack.
2) Place measuring range switch to Ω
meter is in the measurement state.
3) Connect the probe to the both ends of resistor or circuit to be tested.
4) LCD will show readings.
Note:
1) When the input end is open, LCD shows "0L" out-of-range state.
2) When the resistance to be tested > 1MΩ, the meter reading will
be stable after a few seconds, which is normal for high resistance
readings.

4.14 Diode Test

1) Insert black probe to COM jack, insert red probe to INPUT jack.
2) Measuring switch is placed to position Ω
3) Press "FUNC" key to switch to
4) Connect the red probe to diode anode and connect the black probe
to diode cathode.
5) Read on the LCD.
1) What the meter shows is approximation of diode forward
voltage drop.
2) If the probe has reverse connection or the probe is open, the LCD
will show "0L".