4.15 Circuit Continuity Test
1) Insert black probe to COM jack, insert red probe to INPUT jack.
2) Measuring switch is placed to position Ω
3) Press "FUNC" key to switch to
4) Connect the probe to the both ends of circuit to be tested .
5) If the resistance of circuit to be measured is less than 30Ω, the
meter's built-in buzzer may sound.
6) Read the circuit resistance value on the LCD.
Note:
If the probe is open or circuits resistance to be tested is
more than 600Ω, the display will show "0L".
4.16 Capacitance Measurement
1) Insert black probe to COM jack, insert red probe to INPUT jack.
2) Rotary switch is placed to position .
3) After discharging capacitance completely, connect
the probe to the both ends of capacitor to be tested.
4) Read the capacitance on the LCD.
4.17 Surge Current Measurement
1 ) Place rotary switch to position A, press FUNC key to switch AC
current measurement state.
2) Press "INRUSH" key to enter surge current measurement mode, at
this time, LCD shows "- - - -"
3) Hold the trigger, open clamp head, clip one lead of measurement
circuit to be tested in the clamp.
4) When the meter detects surge current activation, the meter will show
and keep surge current value.
5) Read the current value on the LCD display.
circuit continuity measuring state.
Pg 22