2.2.9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists that
could compromise safety, then no electrical supply shall be connected to
the circuit until it is satisfactorily dealt with. If the fault cannot be
corrected immediately but it is necessary to continue operation, an
adequate temporary solution shall be used. This shall be reported to the
owner of the equipment so all parties are advised.
Initial safety checks shall include:
- Those capacitors are discharged: this shall be done in a safe manner to
avoid possibility of sparking;
- That there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
- That there is continuity of earth bonding.
WARNING!
Install the unit in rooms which exceed 6 m².
Do not install the unit in a place where inflammable gas
may leak.
NOTE!
The manufacture may provide other suitable example or
may provide additional information about the refrigerant
odour.
49