Technical Characteristics - Truper COMP-120LV Instructivo

Compresor vertical de banda
Ocultar thumbs Ver también para COMP-120LV:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL CHARACTERISTICS:

Voltage:
220 V~
Frequency:
60 Hz
Current:
10 A
Speed:
3 450 RPM
Motor Rated Power:
3 Hp
Maximum Motor Power: 4 Hp
Maximum Pressure:
116 PSI
Tank Capacity:
31.7 Gal
IP Grade:
IP20
Air Flow:
7,7 CFM - 40 PSI
5,7 CFM - 90 PSI
Power Cord Grips Type: Y
All conductors are: 1,5 mm
Temperature
Build quality: Basic insulation.
Insulation quality: Class l
Thermal insulation of motor winding: Class B
To avoid risk of electrical shock or serious accident,
CAUTION
if power cord gets damaged it shall be repaired by the
manufacturer or by Truper
Power cord grips used in this product: Type"Y".
Assembly design in this product causes insulation to be affected
by liquid spills or splashing.
Before gaining access to terminals, all
WARNING
power circuits shall be disconnected.
WARNING
cord extensions with compressors. Using that type of
extension cause power drops resulting in motor potency
loss and overheating. Instead of using an extension
cord increase the compressor's action scope connecting
a longer hose into the outlet. Connect additional hose
lengths as needed.
BELT DRIVE AIR COMPRESSORS.
- Do not use compressed air to clean clothes.
- Do not apply compressed air directly to skin.
- Do not apply compressed air for breathing purposes unless
the air is filtered with a filter specifically for built to that purpose.
- Do not use open-air piping. It could lash out and cause injuries.
- Do not use flammable liquids to clean the compressor.
- Do not use an open fire to inspect inside the compressor or
the pressure deposit.
- Wear eye protection when using compressed air to clean the
unit.
- Use caution not to blow particles towards people: always use
an air gun for cleaning.
- Double-check all the auxiliary fixtures are functioning adequately
and have the right capacity for the application.
- Inspect regularly that all covers are fixed and firmly set.
- Replace all parts, tools and accessories when unfit for a safe
operation.
- Install a check-valve or a cut valve in the inlet piping in case
compressor shall be parallel coupled with a second compressor
or if it will be connected to an air supply system.
- Double-check all piping and hoses connected to the compressor
have the right diameter, and, adequate resistance for the
maximum pressure delivered by the compressor.
- Install the compressor making available an adequate ventilation
air supply towards the unit. Use care not to restrict air ducts
through the inlets in the cover and motor fan.
2
x 3C with 221 ºF Insulating
2
Authorized Service Center
®
We do not recommend using power
INSPECT:
Inspect the pumps' rotation direction during the initial start up.
Verify any modification in the electric components' or
connections.
Turn off the compressor and disconnect from the power outlet.
Ventilate completely before disassembling any component or
making any maintenance service.
INSTALLATION AND VENTILATION
To service the compressor allow adequate access and free space
up and around the unit. It needs adequate protection against
weather. Good ventilation is essential. To gain maximum
efficiency admission air shall be as cold and clean as possible
(37.4 ºF drop in temperature will increase 1% the delivered air
volume). Gas impurities and particles, abrasive dust and corrosive
gasses are especially harmful. The exhaust vapors are hazardous
if compressed air is used to supply breathing devices.
Set the compressor as far away as possible from the work areas
to prevent from suctioning particles generated by the job (paint,
dust, etc.)
WARNING
This unit SHOULD BE USED with
220 V~ to 240 V~
tension. Using a different
TENSION WILL
SEVERELY DAMAGE
the unit.
CONNECTION TO THE MAIN POWER SUPPLY
he compressor shall be set as close as possible to the main
power supply. Double-check the power supply matches the
voltage indicated in the motor nameplate.
This unit must be grounded.
WARNING
The power cables are coded with the
CAUTION
following colors:
GREEN AND YELLOW
BLUE
BROWN
feeding
GROUND
NEUTRAL
CURRENT
This tool is in compliance with
the Official Mexican Standard
(NOM - Norma Oficial Mexicana).