COOKWARE REQUIREMENTS
Compatible
• Drop-in Ranges: Flat base
4¾" to 12" (12.1 to 30.5 cm) in
diameter
• Countertop Ranges: Flat base
4¾" to 10¼" (12.1 to 26.0 cm)
in diameter
• Ferrous stainless steel, iron,
cast iron
Note: Cookware with inferior construction or material may not perform
well. Cookware with a larger base diameter can be used, however only
the area of the cookware above the induction coil will heat. The more
cookware extends past the coil, the more the overall performance will
be reduced.
NOTICE: Equipment Damage Hazard
Not intended for use with aluminum pans with a metal disk
on the bottom. Under high heat, the metal disk will separate
from the pan. These pans may damage your unit and void
your warranty.

FCC STATEMENT

This equipment has been tested and found to comply with Part 18 of
FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
To assure continued compliance, any changes or modifications not
expressly approved by the party Responsible for compliance could void
the user's authority to operate this equipment.
COUNTERTOP RANGE INSTALLATION
mirage
2
Incompatible
less than 4¾"
• Base is not flat
• Base is less than 4¾" (12.1 cm)
in diameter
• Pottery, glass, aluminum,
bronze or copper cookware
• Metal disk on bottom of pan
Mirage
Clearance and Environment Requirements
NOTICE: This unit is not designed to be enclosed or built into any
area. Sufficient airflow must be allowed around the unit.
Blocking the airflow could cause the unit to overheat.
• Rear of the range to any surrounding surface: 4" (10 cm)
• Bottom of the range to any surrounding surface: ¹⁄₂" (2 cm)
• Indoor use only.
• Do not place the equipment on or near heat-producing equipment.
Installation
1. Place the induction range/warmer on a flat stable surface.
2. Plug the power cord into a grounded electrical outlets that match the
voltage on the rating label.
NOTICE: This equipment requires a dedicated circuit.
NOTICE: Using a voltage other than the nameplate rated voltage
will cause damage to the unit. Incorrect voltage,
modification to the power cord or electrical components
can damage unit and will void the warranty.
DROP-IN RANGE INSTALLATION
Before you begin
1. Download the specification sheet for your drop-in from
Vollrath.com. You will need to refer to this document for
dimensions, clearance, venting and power requirements.
2. Verify the proper electrical outlet is available at the installation site.
NOTICE: This equipment requires a dedicated circuit.
NOTICE: Do NOT modify the cord or plug on the drop-in. Modifying
any component may damage the drop-in or cause injury,
and will void the warranty. See the specification sheet on
Vollrath.com for electrical specifications.
3. Know the countertop manufacturer's requirements for preparing and
installing equipment into the countertop prior to starting installation.
Prepare the Countertop and Cabinet
NOTICE: Refer to the drop-in specification sheet for cutout
dimensions, air flow and venting requirements, minimum
clearance distances and environment requirements.
NOTICE: Countertop materials require specific preparation. Refer to
the countertop manufacturer for instructions regarding
proper installation of equipment into the material.
NOTICE: Exposed wood or particle board edges must be sealed with
an appropriate waterproofing material. Seal the edge
between the glass and the countertop with silicone or
similar material. Failure to do so may result in damage to
the countertop.
1. Cut required openings in the countertop and cabinet.
2. Clean debris from the cut out area(s).
3. Reinforce the countertop support as needed per the countertop
manufacturer guidelines and the weight of the equipment.
Mount the Drop-in
1. Choose a flat, level countertop for the mounting surface.
2. Measure the area for the cutout, including the countersink area. The
unit is designed to be countersunk. The depth of the surface around
the cutout must be reduced to allow for the countersink. See the
specification sheet.
®