TROUBLESHOOTING
Problem
Energizer has started to run
slowly
Displaying Error 11
Displaying Error 12
Displaying Error 14 - 19
Displaying Error 21
Energizer output voltage is
low
Earth voltage is too high
No output and display shows
( - - )
Save these instruc ons
Causes
The internal temperature of
the energizer is too high
Mains voltage is too high
Mains voltage is too low
Internal energizer fault
Dead zone
There is a fault on the fence
Earth system is inadequate
Energizer is in standby mode Exit standby mode by
Solution
Mount the energizer in a cool
area, out of direct sun and
with adequate ven la on
Have your power supply
checked by a professional
electrician
Have your power supply
checked by a professional
electrician
Turn energizer off for 30
seconds then turn back on. If
the error remains return the
energizer to your Gallagher
dealer for servicing.
Check that the zone device
is connected and working
correctly.
Remove any excess grass
growth or short circuits on
the fence.
Check connec ons to the
earth system. Add extra
earth stakes.
pressing the standby bu on
on the controller
19