Gallagher M1200i Manual De Instrucciones página 15

Ocultar thumbs Ver también para M1200i:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
Gallagher 3E2488 M1200i Energizer User Manual
Current Alarm
The factory default se ng is current alarm disabled (shown by --). To improve
your ability to fi nd faults before your fence becomes ineff ec ve (voltage too low),
Gallagher recommend se ng the current alarm 10A above normal opera on.
Many events can cause the current to increase, including rainfall, grass growth,
broken fences and failed insulators. If the current goes above the alarm level you
have set, then the Energizer icon (
Status LED
fl ashes red
Adjus ng / Turning Off Alarms
a)
Press the setup bu on (
b)
Press the naviga on bu ons (< or >) to move the zone indica on arrow (
over the desired zone, which will fl ash when selected.
c)
Press (- or +) to adjust the zone alarm level. The higher the alarm level is set,
the more sensi ve the zone will be to faults.
d)
To disable an alarm press (-) un l the display shows (- -).
e)
To exit, press the setup bu on (
) will fl ash and the status LED will fl ash red.
Controller showing the energizer in current alarm
).
Controller showing the energizer alarm setup at 3.0KV
) or wait 10 seconds.
)
15

Publicidad

Tabla de contenido
loading

Tabla de contenido