Facom CL3.CTB50 Manual Original página 18

Alicate para abrazadera electroportatil
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Color
Mode
Flashing
Temporary fault
orange
Red Flashing
Prolonged fault
Green
Used battery
Flashing
8.2 MAINTENANCE LEVEL
Level 1 Maintenance
When the blade or head are worn, level 1 preventive maintenance can be performed by personnel authorized to
perform maintenance and having read the maintenance manual.
It includes:
-
Changing the clamping head
-
Regular changing of the blade (guaranteeing perfect cutting – about every 30,000 cuts).
Level 2 Maintenance
Level 2 maintenance comprises all other operations on this product. It is ensured exclusively by FACOM. The user
is not authorized to open the tool , whatever the intervention involved.
Only FACOM approved personnel can intervene to ensure upgrading or repairs.
8.3 AFTER SALES SERVICE
For any question or intervention on the tool, call your FACOM dealer.
8.4 SPARE PARTS
The following spare parts are available:
-
Parts available for CL3.CTB50:
 Maintenance kit: CL3.CTB50-MK
 Spare blades: CL3.CTB50-SB
-
Parts available for CL3.CTB120:
Maintenance kit: CL3.CTB120-MK
Spare blades: CL3.CTB120-SB
-
Battery reference:
-
Charger reference:
-
Suspension hook reference:
-
Nomad kit/Holster kit:
 Belt reference:
 Right holster reference:
Or Left holster reference:
9.
SPECIFICATIONS
Model
Operation ambient
temperature
CL3.CTB50
5°C – 45°C
CL3.CTB120
5°C – 45°C
NU-CL3.CTB50 - CL3.CTB120_0216.indd 18
Description
Overheating detected on the pliers. Operation is blocked until the
tool is cooled sufficiently. The system's operation is restored once
the conditions leading to safety mode have disappeared.
A problem preventing clamp operation was detected on the pliers.
Send the pliers to the maintenance manager.
When connecting the battery, the indicator flashes green during
5 seconds to indicate that the battery is low (>500 charging/
discharging cycles). It remains usable but with lower performance.
CL3.CTB-BA
CL3.CTB-CH
CL3.CTB-SH
CL3.CTB-B
CL3.CTB-HR
CL3.CTB-HL
Temperature
Clamping
Storage
force
0°C – 45°C
<= 300 N
0°C – 45°C
<= 300 N
18
Clamping speed
Weight
6 cycles/minutes
880g
6 cycles/minutes
900g
2/9/2016 4:25:29 PM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cl3.ctb120

Tabla de contenido