13
LIFT ARM
FIRST
IMPORTANT: Always
clear sand and rust
from system.
• Make sure water supply is
off. Remove valve TOP by
lifting arm and rotating top
and arm 1/8 turn
counterclockwise, pressing
down slightly on cap.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products.
Fluidmaster shall not be responsible or liable for any damages caused by products used
with Fluidmaster valves that were not manufactured by Fluidmaster, Inc.
PART NUMBER
735169.XXX0A
5218.110.XXX
7381073-XXX0A
738565-457 .0070A
7381206-400.0070A
7381213-100.0070A
7381203-200.0070A
PROBLEM
POSSIBLE CAUSE
Does not flush
a. Water supply valve closed.
b. Supply line blocked.
c. Sand or debris lodged in water control.
Poor or sluggish flush
a. Tank water too low.
b. Bowl water too low.
c. Water supply valve partly closed.
d. Partially clogged trapway and/or drain pipe and/or vent.
e. Water supply pressure too low.
Toilet leaks
a. Poor supply line connection.
b. Poor bowl to floor connection.
Toilet does not shut off
a. Flush valve seal leaking or deformed.
b. Sand or debris lodged in water control.
c. Water level set too high.
• While holding a
• Replace TOP by engaging
container over the
lugs and rotating 1/8 turn
uncapped VALVE to
clockwise. MAKE
prevent splashing, turn
CERTAIN TIP IS TURNED
water supply on and off
TO THE LOCKED
a few times. Leave
POSITION. VALVE MAY
water supply off.
NOT TURN ON IF TOP IS
NOT FULLY TURNED TO
THE LOCKED POSITION.

REPAIR PARTS LIST

NOTE: "XXX" represents color options. Specify when ordering.
DESCRIPTION
Tank Cover
Slow Close Contemporary EL Seat
Bolt Cap Cover Kit
Inlet Valve
Dual Flush Valve Assembly
Dual Flush Valve Seal
Push Button Kit

TROUBLESHOOTING GUIDE

IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK
SLOWLY, repeat Step 13.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF
NON-USE, it is a signal you are wasting water because:
• The end of the refill tube is inserted into overflow pipe, below
water level in tank. Attach refill tube to overflow pipe using
"S" clip provided.
• The flush valve is leaking because it's worn, dirty or misaligned
with tank ball or flapper (replace with a new flapper).
IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL
OF TANK WATER IS SLOW after valve has been in use for
some time, Fluidmaster Model 242 Replacement Seal may
be needed.
Go to our website at www.fluidmaster.com for more
solutions to toilet problems.
For troubleshooting information please contact:
CORRECTIVE ACTION
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all gaskets and washers.
Reassemble.
c. See Fluidmaster maintenance. (see Step 13)
a. Check that the water level is set to the mark inside the tank.
b. Check that the refill tube is connected to the water control and flush valve port.
Adjust refill float down until bowl water is restored. (see Step 9)
c. Open water supply valve fully. Be sure that proper water supply tube size is used.
d. Remove obstruction. Consult a plumber if necessary.
e. Minimum water supply pressure - 20psi. Wait for tank to refill.
a. Review Step 8a and 8b.
b. Review Step 4 through 6.
a. Clean debris from seal surface. Replace flush valve seal as needed.
b. See Step 13 Fluidmaster maintenance.
c. Set water level to mark on back of tank.
- 4 -
TROUBLESHOOTING
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675
(949) 728-2000 (800) 631-2011
www.fluidmaster.com
© 2001 Fluidmaster, Inc.
® Registered trademark of Fluidmaster, Inc.
73016 90 -10 0 Rev. C