Installation
3
Make Electrical Connections
WARNING! Your Sentry Washfountain MUST be connected to 24 VAC transformer provided. Connection to
110 VAC will result in damage to the electronics and could result in personal injury. Refer to Instruction
Sheet 215-1503 for more information.
STOP!!! If installing optional Shroud/Slip Ring or Towel Dispensers,
complete those installations before proceeding to Step 4 (see next page).
Compression Nut
Navigator Mixing
Valve or Tempered
Line Adaptor
Bradley • 215-1762 Rev. A; ECN 14-00-007
Green Supply Tube
Black Supply Tube
Top
1
2
3
Green
Left Button
(Black)
3
Red Supply
Tube
24 VAC from transformer .
Attach minimum 18-gauge
wires (supplied by installer) to
transformer screw terminals
using 1/4" Quick-Connects .
Gray
Center Button
(Green)
2
SN2013/TT, SN2033/TT
Transformer
(269-645)
Terminal Block
Red
Black
Black
Right Button
(Red)
1
10/21/2014
(269-1311)
Top
Brown
7