Cooper Champ FMV Serie Información De Instalación Y Mantenimiento página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Loosen bolts to
set floodlight
angle
2.
Re-install the back cover and tighten all eight (8) cover mounting screws 6.6 ft.-lbs., 9.04 N•m.
3.
Replace any damaged or missing cover screws. Use only stainless steel 1/4-20 x .625" cover
screws.
4.
To make final vertical adjustment, loosen the pivot bolts on the floodlight yoke to position
floodlight at the desired angle (limited to 60 degrees forward and 45 degrees back).
To avoid ignition of the hazardous atmospheres or overheating of the floodlight:
Do not position the floodlight beyond the aiming range limits.
5.
Rotate the floodlight housing to the desired position.
6.
Tighten the two (2) pivot bolts to 45 ft.-lbs., 61 N•m.
7.
Turn power on.
DIMENSIONS
IF 1622 • 08/12
Figure 3
WARNING
532.9
21.0
405.9
16.0
552.5
21.75
14
Ø .55
120.7
4.75
Copyright
MAINTENANCE
Perform visual, electrical, and mechanical inspections on a regular basis. The environment
and frequency of use should determine this. However, it is recommended that checks be
made at least once a year. We recommend an Electrical Preventive Maintenance Program as
described in the National Fire Protection Association Bulletin NFPA 70B: Recommended
Practice for Electrical Equipment Maintenance (www.nfpa.org).
The lens should be cleaned periodically to ensure continued lighting performance. To clean,
wipe the lens with a clean damp cloth. If this is not sufficient, use a mild soap or a liquid
cleaner such as Collinite NCF or Duco #7. Do not use an abrasive, strong alkaline, or acid
cleaner. Damage may result.
Visually check for undue heating evidenced by discoloration of wires or other components,
damaged parts, or leakage evidenced by water or corrosion in the interior. Replace all worn,
damaged, or malfunctioning components and clean gasket seals before putting the luminaire
back into service.
Electrically check to make sure that all connections are clean and tight.
Mechanically check that all parts are properly assembled.
REPLACEMENT PARTS
Cooper Crouse-Hinds Champ
performance. However, should the need for replacement parts arise, they are available through your
authorized Cooper Crouse-Hinds distributor. Assistance may also be obtained through your local
Cooper Crouse-Hinds representative or the Cooper Crouse-Hinds Sales Service Department, P.O. Box
4999, Syracuse, New York 13221, Phone 866-764-5454.
167.1
6.6
©
2012, Cooper Industries, Inc.
®
LED Floodlights are designed to provide years of reliable lighting