Cooper Champ FMV Serie Información De Instalación Y Mantenimiento página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VISOR INSTALLATION INSTRUCTIONS
1.
Remove power from floodlight.
2.
Place floodlight face up.
3.
Carefully align visor with two (2) screw holes at the top of the fixture shown in the image above.
4.
Install screws provided with visor, taking care to not scratch the finish of the floodlight. Torque to
6.6 ft.-lbs., 9.04 N•m.
5.
Install floodlight per above instructions.
NOTE: Visor can be installed before or after floodlight has been in operation.
Conditions of safe use: the following fasteners are used to secure enclosure for protection method "tc."
1. 1/4 - 20 x .625" - Back cover to driver housing - hex slotted screw.
2. 1/4 - 20 x .438" - LED housing to Bezel cross recess screw.
3. 1/4 - 20 x .750" - Driver housing to LED housing cross recess screw.
Items 2 & 3 are not intended to be opened.
The above fasteners shall only be replaced with identical ones.
All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable.The accuracy or completeness thereof are not guaranteed. In
accordance with Crouse-Hinds "Terms and Conditions of Sale," and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and
assumes all risk and liability whatsoever in connection therewith.
With Visor and Guard
With Visor Only
Table 1
Cooper Industries Inc.
Crouse-Hinds Division
PO Box 4999, Syracuse, New York 13221 • U.S.A.
Copyright
GUARD INSTALLATION INSTRUCTIONS
1.
Remove power from floodlight.
2.
Place floodlight face up.
3.
Carefully align guard with four (4) screw holes on each side of the fixture shown in the image
above.
4.
Install screws provided with guard taking care to not scratch the finish of the floodlight. Torque
to 6.6 ft.-lbs., 9.04 N•m.
5. Install floodlight per above instructions.
NOTE: Guard can be installed before or after floodlight has been in operation.
NOTE: Visor and guard can both be used on a floodlight at the same time. Visor and guard are
always installed in the field and are not factory installed, therefore, field installation is acceptable and
will not affect the fixture's ratings.
©
2012, Cooper Industries, Inc.
With Guard Only
Floodlight with Visor
and Guard Shown
IF 1622
Revision 3
Revised 08/12
Supercedes 07/12

Publicidad

Tabla de contenido
loading

Tabla de contenido