In installations with long lengths of power lines, it is re-
commended to lengthen the 230V ~AC line and install the
transformers near the projectors, and if necessary, lengthen
the 12V~AC line towards the DMX modulator (code 41109),
which controls the projectors:
In accordance with the previous diagram, for correct opera-
tion, the cable sections should be suitable to the length of
the cable. The sections and lengths for a line in which there
is only one modulator, without any projector, are given below:
Modulator Line (m)
150 - 300
0 - 50
For a line in which there are projectors, the sections are lengths are:
1 projector in the line
L. Projector (m)
LumiPlus
LumiPlus 1.11
2.0 / Design
55 - 90
45 - 80
35 - 55
30 - 45
20 - 35
18 - 30
14 - 20
10 - 18
0 - 14
0 - 10
5 projectors in the line
L. Projector (m)
LumiPlus
LumiPlus 1.11
2.0 / Design
10 - 18
9 -12
7 - 10
6 - 9
4 - 7
2 - 6
0 - 4
0 - 2
A modulator and projectors can be in the same line.
Do not install the 12V~AC power lines of the projectors and modulators near possible electrical interference of other
signals.
Section
2
2,5mm
Cu
2
1,5 mm
Cu
Section
LumiPlus 1.11
2
10 mm
Cu
20 - 45
2
6 mm
Cu
18 - 25
2
4 mm
Cu
10 - 18
2
2,5 mm
Cu
2
1,5 mm
Cu
Section
LumiPlus 1.11
2
10 mm
Cu
2
6 mm
Cu
2
4 mm
Cu
2
2,5 mm
Cu
2 projector in the line
L. Projector (m)
LumiPlus
2.0 / Design
20 - 40
15 - 20
8 - 15
7 - 10
5 - 8
0 - 7
0 - 5
10 projectors in the line
L. Projector (m)
LumiPlus
2.0 / Design
0 - 9
0 - 6
3
Section
2
10 mm
Cu
2
6 mm
Cu
2
4 mm
Cu
2
2,5 mm
Cu
2
1,5 mm
Cu
Section
2
10 mm
Cu

Publicidad