Checks Before Commissioning; Calibrating The Sensor; Priming The Peristaltic Pump; Boost» Mode - Zodiac Chlor expert Manual De Instalación Y De Uso

Ocultar thumbs Ver también para Chlor expert:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
Thanks to its double electrical supply, the appliance is always powered on, even if fi ltering is stopped, making it
possible to view the water disinfectant capacity (potenti al Redox) at all ti mes. The sensor can also be calibrated
when fi ltering is stopped.
The appliance can be powered off at all ti mes using the 0-1 switch on the side of the appliance.

3.2 Checks before commissioning

• The sucti on tube must be immersed in the disinfectant product container with the sucti on cane and is connected to the
peristalti c pump (left side).
• The injecti on tube is connected on one side to the peristalti c pump (right side) and on the other side to the pool
discharge pipe via the injecti on valve.
• The peristalti c pump cover must be refi tt ed using its fi xture screw.
3.3 Calibrati ng the sensor
For the appliance to operate accurately and reliably, the Redox sensor must be calibrated regularly (on instal-
lati on, on re commissioning aft er wintering, and every 2 months when in use).
• Rinse the ti p of the Redox sensor with clean water.
• Shake it to remove excess water.
Don't wipe the sensor or touch its ti p!
• Plunge the sensor into the bott le of 465 mV buff er soluti on.
• Press
the
butt on
• Press
, the progress bar is displayed:
• Aft er about 30 seconds the Redox sensor reliability appears as a percentage. If the value is above 25% press
complete the calibrati on, otherwise power off the appliance using the 0-1 butt on, change the buff er soluti on and/or the
Redox sensor and start the calibrati on again.
• Rinse the ti p of the Redox sensor with clean water.
• Shake it to remove excess water.
• Fit the sensor back onto its holder.
3.4 Priming the peristalti c pump
The peristalti c pump is self priming. However, it can be run manually by pressing
run to inject corrector product as long as the key is kept pressed down.
3.5 «Boost» Mode
This appliance is fi tt ed with a functi on to quickly increase the pool's free chlorine level (in the event of stormy weather or
a high number of bathers, etc.). The «Boost» mode durati on is set to 10 minutes by default.
When the appliance is powered on, press
When «Boost» mode is acti ve the
3.6 Setti ngs
3.6.1 «Setti ngs» menu
Menu
Language
Set point
«Boost» mode durati on
«OFA» overdose safety system
Calibrati on
Filtering operati on detecti on
H0435000.A - EN - 2013-11
for
5
seconds
unti l
,
and
at the same ti me for 5 seconds to acti vate «Boost» mode.
French
650 mV
10 minutes
4 hours
Acti vated «On»
Acti vated «On»
,
. The peristalti c pump will then
screen is displayed with the remaining ti me.
Default Setti ngs
is
displayed,
then
EN
to
6

Publicidad

Tabla de contenido
loading