Chiseling power can be reduced to approx. 70% by pressing the power level selector switch. The power
level LED then lights up, indicating reduced power.
3.6

Service indicator information

The breaker is equipped with a service indicator LED.
Status
The service indicator lights red.
The service indicator blinks red.
Bring the product to Hilti Service in good time. This will help to ensure that it's always ready for use.
3.7
Items supplied
Breaker, side handle, operating instructions.
You can find other system products approved for your product at your local Hilti Center or online at:
www.hilti.group.
4

Technical data

4.1
Breaker
For details of the rated voltage, current, frequency and/or input power, please refer to the power tool's
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Weight in accordance with EPTA procedure 01
Single impact energy in accordance with EPTA
procedure 05
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
Sound (power) level (L
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
*2190680*
)
)
WA
)
pA
)
pA
2190680
Meaning
End of service interval – servicing is due.
A fault has occurred in the tool.
The overheating prevention cut-out has been acti-
vated.
The voltage provided by the electric supply is too
high.
TE 1000­AVR
12.5 kg
26 J
96 dB(A)
3 dB(A)
85 dB(A)
3 dB(A)
English