7. Operation
The instrument will automatically quit the setting mode if no button is pressed within 10
seconds.
7.1 Manual setting of the clock
Press and hold the "MENU/SETUP" button for 2 seconds to enter setting mode. The hour
indicator is flashing and with the "▲" or "▼" button adjust the setting. Holding the "▲"
or "▼"" button, you will enter fast mode. Confirm with the "MENU/SETUP" button.
Set minutes in the same way. Confirm with the "MENU/SETUP" button.
"On" appears on the display. The DCF time is activated. If DCF reception is on, the manu-
ally set time will be overwritten by the DCF time when the signal is received successfully.
To turn off the DCF time, press the "▲" or "▼" button. "Off" appears on the display. Con-
firm with the "MENU/SETUP" button.
7.2 Setting of the alarm
Press the " " button to select alarm time. The alarm time appears on the LCD for
10 seconds.
To activate or deactivate the alarm function press the " " button again.
The alarm icon is shown on the display of the station as soon as the alarm is activated.
Press the " " button for 2 seconds to enter alarm time setting. The hour indicator
is flashing and with the "▲" or "▼" button adjust the setting. Holding the "▲" or "▼"
button, you will enter fast mode. Press the " " button to confirm it.
Set minutes in the same way. Press the " " button to confirm it.
The alarm time appears on the display (max. 10 sec.).
When alarm is sounding, press any button to stop the alarm.
When alarm is sounding, wave hand within max. 15 cm distance to activate snooze func-
tion. The alarm symbol is flashing and the alarm will be interrupted for
5 minutes.
Press any button to stop the snooze function.

8. Weather forecast

There are 5 different weather symbols (sunny, slightly cloudy, cloudy, rain and storm)
and 3 different symbols for the trend of atmospheric pressure (increasing, steady,
decreasing).
9. Maximum/Minimum function
Press the "MAX/MIN" button to show the maximum
temperature.
Press the "MAX/MIN" button again to show minimum
Press the "MAX/MIN" button for 2 seconds to clear the recorded maximum and minimum
reading.
10. Positioning of base station and the transmitter
Choose a shady and dry position for the transmitter. (Direct sunshine falsifies the meas-
urement and continuous humidity strains the electronic components needlessly)
Place the base station in the living room with the additional table stand. With the suspen-
sions device you can fix it on a wall. Avoid the vicinity of any interfering field like comput-
er monitors or TV sets and solid metal objects.
Check the transmission of 433 MHz signal from the transmitter to the display unit (trans-
mission range 30 m free field). Within ferro-concrete rooms (basements, superstruc-
tures), the received signal is naturally weakened.
If necessary, choose another position for transmitter and/or base station.
14
27.01.2021
10:36 Uhr
Seite 8
values of indoor and outdoor
values.
LUMAX
– Wireless weather station
11. Additional transmitters
The transmitter will automatically transmit temperature to the base station on channel 1
after batteries are inserted.
For having more than one external transmitter, select a different channel (1 to 3)
for every transmitter by pressing the "CH" button on the transmitter while the transmis-
sion indication LED is flashing. Press twice for channel 2 and three times for channel 3
right after the starting up of the transmitter. The LED is flashing once for channel 1, twice
for channel 2 and three times for channel 3 (channel 4 and 5 are not usable for this
weather station).
Press and hold the "CH" button on the display unit for 2 sec. to start initialization manual-
ly. The channel number on the LCD of the display unit flashes and the new transmitter will
be received automatically.
The temperature measured by the sensor is shown on the display of the display unit. If
you have installed more than one transmitter, press "CH" button (on the display unit) to
change between the outdoor transmitters.
You can also choose an alternating channel display. Press "CH" button after the last regis-
tered channel and all sensors appear alternating.
12. Care and maintenance
Clean the instruments with a soft damp cloth. Do not use solvents or scouring agents.
Remove the batteries and pull out the plug of the socket, if you do not use the product for
a long period of time.
Keep the devices in a dry place.

12.1 Battery replacement

Replace the batteries when the battery symbol of the weather station appears on the dis-
play on the top left hand. If operation is exclusively with the mains adapter, the battery
symbol is displayed permanently.
When the batteries of the transmitter are used up, the low battery icon appears next to the
outdoor temperature display.
Open the battery compartments and insert the new batteries. Make sure they have the
correct polarity. Close the covers again.
Please note: When the batteries are changed, the contact between transmitter and
receiver must be restored – so always insert new batteries into both units or start a man-
ual transmitter search.

13. Troubleshooting

Problems
Solutions
➜ Connect unit to mains adapter
No indication on the display
of the weather station
➜ No transmitter is installed
No reception of the
➜ Check batteries of external transmitter
outdoor transmitter
Display "---"
➜ Restart the transmitter and weather station
for channel 1/2/3
➜ Start the manual search for the transmitter
➜ Choose another place for the transmitter
➜ Reduce the distance between the transmitter
➜ Check if there is any source of interference
(do not use rechargeable batteries!)
according to the manual
and/or the weather station
and the weather station
15