CAUTION
The strap of the fasteners must have good contact with the plate on the upper part. The black arrow markings
must be aligned so that they point at each other.

Filter cleaning

The machine has a filter status indicator that lights up when the filter needs to be cleaned or replaced. The filters must be cleaned
1-2 times a day with continuous use .
The filters should be cleaned when the manometer is in the red field.
1.
Keep the machine switched on and close the throttle at the cyclone inlet. Reset the filter cleaner button.
2.
Wait for 5-10 pulses.
3.
Switch off the machine.
4.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
5.
Switch on the machine.
6.
Check that the pressure gauge indicates green or that the filter indication lamp is off. If not, repeat the procedure. If the
gauge indicates red or the light is on even after repetition, the fine filter needs to be replaced. If it, despite the filter change,
still indicates red, the vacuum valve must be checked.