Pressure generation and air flow
Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications. If using an extension
cord, it must be water-resistant.
Filter cleaning
1.
Keep the machine switched on and close the throttle at the cyclone inlet. Reset the filter cleaner button.
2.
Wait for 5-10 pulses.
3.
Switch off the machine.
4.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
5.
Switch on the machine.
6.
Check that the pressure gauge indicates green or that the filter indication lamp is off. If not, repeat the procedure. If the
gauge indicates red or the light is on even after repetition, the fine filter needs to be replaced. If it, despite the filter change,
still indicates red, the vacuum valve must be checked.
16
DC Tromb, Art.nr. 9480-I