Operation; Filter Cleaning - Dustcontrol DC 5900 Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Connection dimension
Rec. quick coupling and pneumatic hose
Filter area, HEPA filter [m
Filtration efficiency (EN 1822-1) [%]
Efficiency, fine filter, EN 60335-2-69, Class H [%]
Filter classification, EN 1822-1
Sound level [dB(A)]
Pressure generation and air flow

Operation

Connect the machine to a compressed air system with sufficient pressure and air volume. See Technical data. The feed (hose)
must be anti-static or grounded. The swiveling anti-static wheels must be in contact with a conductive surface.
WARNING
Too low main pressure and small dimensions of the compressed air line will result in poor performance.

Filter cleaning

The machine has a filter status indicator that lights up when the filter needs to be cleaned or replaced. The filters must be cleaned
1-2 times a day with continuous use .
1.
Keep the machine switched on and close the throttle at the cyclone inlet. Reset the filter cleaner button.
2.
Wait for 5-10 pulses.
3.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
4.
Check that the pressure gauge indicates green or that the filter indication lamp is off. If not, repeat the procedure. If the
gauge indicates red or the light is on even after repetition, the fine filter needs to be replaced. If it, despite the filter change,
still indicates red, the vacuum valve must be checked.
2
]
DC 5900, Art.nr. 9458-F
R 1"
1"
2.5 (Accessories)
99.9
99.95
HEPA H13
> 75
15

Publicidad

Tabla de contenido
loading

Tabla de contenido