38
progress
Connections
DUCTING VERSION AIREXHAUST SYS-
When installing the hood in ducting version, a rigid
or a flexible pipe with the diameter corresponding
to the flange diameter is used in order to connect
the hood to the air outlet piping.
• Fix the pipe with an adequate quantity of pipe
clamps (not supplied).
• Remove possible charcoal filters.
RECIRCULATION VERSION AIREOUT-
• Cut a hole ø 125 mm in any shelf that may
be posi-tioned over the hood.
• Connect the flange to the outlet on the shelf
over the hood using a flexible or rigid pipe
ø120 mm.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Fix the directional grille 8 on the recirculation
air outlet using the 2 screws 12e (2,9 x 12,7)
provided.
• Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a
two-pole switch having a contact gap of at
least 3 mm.
• When opening the sliding carriage for the first
time after installing the hood, pull it out briskly
until it clicks.