ELECTRICAL REQUIREMENTS

This appliance must be electrically grounded.
Check with your local codes which apply in your area.
If no local codes apply, the National Electrical Code,
ANSI/NFPA No. 70-Latest Edition must be followed.
Write to:
NATIONAL FIRE PROTECTION
ASSOCIATION
BATTERYMARCH PARK
QUINCY, MA 02269
Be sure the installation of this cooktop in a mobile home
conforms with the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280. If this
standard does not apply, you must follow the standard
for Manufactured Home Installations, ANSI A225.1 and
Manufactured Home Installations, Site and Communities
and ANSI/NFPA 501A or with local codes. You can get
a copy of the Federal Standard by writing:
Office of Mobile Home Standards
HUD Building
451 7th Street, S. W.
Washington, D.C. 24010

PREPARE THE OPENING

Fig. 1
35 1/2"
18 15/16"
2 1/4"
3 1/4"
Fig. 2
21"
COOKTOP
33 11/16"
19 3/16"
16 15/16"
33 7/8"
1"
FROM BACKWALL
12 1/2"
FROM CUTOUT
CENTER LINE
Fig. 3
30" MIN.
TO CABINET
3 3/4" MIN.
CLEARANCE
TO SIDE WALL
• Make sure the wall coverings, countertop and cabi-
nets around the cooktop can withstand the heat (up
to 200 ° F) generated by the cooktop.
• Provide adequate clearances between cooktop and
adjacent combustible surfaces.
PROVIDE ADEQUATE GAS SUPPLY
This cooktop is designed to operate on natural gas at 4"
of water column pressure. It is shipped from the factory
set for natural gas.
FOR PROPER OPERATION, THE MAXIMUM
INLET PRESSURE TO THE REGULATOR MUST
BE NO MORE THAN 14" OF WATER COLUMN
PRESSURE. For checking the regulator, the inlet
pressure must be at least 1" (or 3.4 KPA) greater than
the regulator output setting. If the regulator is set for 4"
3"
of water column pressure, the inlet pressure must be at
least 5". If the regulator is set for 10", the inlet pressure
must be at least 11".
The gas supply line to the cooktop should be 1/2" or
3/4" pipe.
2
13"
MAX.
DEPTH
3 3/4" MIN.
CLEARANCE
TO SIDE WALL
18" MIN.
TO CABINET