Installation requirements location
This appliance must be installed on firm flooring to minimize
vibration during spin cycle. Concrete flooring is best, but
wood base is sufficient, provided floor support meets FHA
standards. This appliance should not be installed on rugs or
exposed to weather.
Plumbing
WATER PRESSURE - Must be 20 psi minimum to 120 psi
maximum.
WATER TEMPERATURE - Household water heater should be
set to deliver water at 120 °F (50 °C) IN THE WASHER when
hot wash is selected.
SHUTOFF VALVES - Both hot and cold shutoff valves (fau-
cets) should be supplied.
DRAIN - Water may be drained into standpipe or set tub.
Discharge height MUST NOT BE LESS THAN 30 INCHES,
and no more than 8 feet above the base of the washer.
Standpipe must be 1-1/2 inches minimum inside diameter
and must be open to atmosphere.
Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of ap-
pliance (see section 1).
Step 3 Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 6).
Step 4 Remove the Foam Shipping Pads (see section 1).
Step 5 Move the appliance to the Desired Location.
Step 6 Level your appliance (see section 8).
Step 7 Connect the Gas Supply (see section 3) and check for
leaks (see section 4).
Step 8 Connect the External Exhaust (see section 7).
Step 9 Connect to plumbing facilities (see section 11).
Step 10 Connect the Power Supply (see section 5).
Step 11 Check the Operation of the Power Supply, Gas Con-
nections, and Venting.
20
CAUTION:

electrical requirements.

CAUTION:
or adapter plug with this appliance. Do not, under any cir-
cumstances, cut or remove the third grounding prong from
the power cord. Follow national electrical codes and ordi-
nances. This appliance must be supplied with the voltage and
frequency indicated on the rating plate (located at the top
of the dryer front panel), and connected to an individual,
properly grounded branch circuit, protected by a 15- or 20-
amp circuit breaker or time-delay fuse. If the electric supply
provided does not meet the above requirements, call a li-
censed electrician.

Installation Sequence

Step 12 Place the Use & Care Guide in a Location Where
They Will Be Noticed By the Owner.
For Alcove or Closet Installation see section 13.
For Bathroom or Bedroom Installation see section 14.
For Mobile or Manufactured Home see section 12.
Electrical requirements
Before plugging in washer, read the following
For personal safety, do not use an extension cord