Venta AW902 Manual De Instrucciones página 31

Ocultar thumbs Ver también para AW902:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
Reminder/Interval Actions
Attention! Ensure that the device is switched off during the following actions
!
and the power plug is disconnected from the power supply!
B CHANGE
HYGIENE DISC
SERVICE
Recommenda-
tion
every 3 years
You can carry out the maintenance steps CHANGE HYGIENE DISC, SERVICE and
CLEANING whenever necessary. When you are finished, simply tap the relevant
RESET button in the maintenance menu
reset. The next reminders for the actions performed will be indicated at the normal
intervals.
Any residues in the water tray and on the VentWave™ disk stack (white, green-yel-
low or brown deposits or discolorations) do NOT impair the function of the device.
Open evaporator compartment. Remove VentWave™ disk stack
and unlock the drive wheel. Remove hygiene disk and replace it.
Re-assemble the appliance and switch it on. Tap
the display to access the maintenance menu. Then tap RESET
next to CHANGE HYGIENE DISC and hold for 3 seconds until the
time is reset.
After 3 months, the maintenance button
i
and indicates that this action is necessary.
The service life of a hygiene disk is approx. 3 months (at con-
tinuous 24-hour operation) and depends on the water hardness,
water quality, daily evaporation performance and number of
operating hours.
You can use the Venta ReNew recycling program to return
the hygiene disk to us (see RECYCLING & DISPOSAL).
Empty the residual water out of the water tank and water tray.
Clean the water tray, VentWave™ disk stack and water tank un-
der running water. Fill the water tank up to the MAX marker with
fresh water. Re-assemble the appliance and switch it on. Tap
button on the display to access the maintenance menu. Then
tap the RESET button next to SERVICE and hold for 3 seconds
until the time is reset.
After 14 days, the maintenance button
i
and indicates that this action is necessary.
To ensure the full performance of the UVC lamp, you should
change the bulb every 3 years.
Note: UVC lamp is on for 4 h per day or 1 h in timer mode.
and hold for 3 seconds until the time is
button on
lights up in red
lights up in red
EN
31

Publicidad

Tabla de contenido
loading

Tabla de contenido