Service Menu - Lamborghini Caloreclima FL 24 TCS Instrucciones De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A - Upstream pressure point
B - Downstream pressure point
R
I - Gas valve electrical connection
R - Gas outlet
S - Gas inlet
B
I
A
TYPE SGV100
Pi max 65 mbar
24 Vdc - class B+A
S
fig. 18 - Gas valve
Heating power adjustment
To adjust the heating power, switch the boiler to TEST mode (see sec. 4.1). Press the
heating buttons detail 3 - fig. 1 to increase or decrease the power (min. = 00 - max. =
100). Press the reset button within 5 seconds and the max. power will remain that just
set. Exit TEST mode (see sec. 4.1).
Configuration Menu
Press the DHW buttons together for 10 seconds to access the configuration Menu. 8 pa-
rameters are available, indicated by the letter "b", which are not modifiable from Remote
Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
Contents Description
Range
0=Natural Gas
b01
Gas type selection
1=LPG
1=Bithermal
instantaneous
2=Monothermal
instantaneous
b02
Boiler type selection
3=Heating only
(3-way valve)
4=Heating only
(circulating pump)
0=Sealed Chamber
combustion control
(without fume
pressure switch)
1=Open Chamber
(with fume thermostat)
2=Sealed Chamber
(with fume pressure
switch)
3=Sealed Chamber
Combustion chamber type
b03
combustion control
selection
(with fume thermostat
on recuperator)
4=LOW NOx Sealed
Chamber Combustion
control
(without fume
pressure switch)
5=LOW NOx Open
Chamber
(with fume thermostat)
18
EN
1 2 3 4
~ 24W
fig. 19 - Gas valve connection
Default
0=Natural Gas
0=Natural Gas
1=Bithermal instanta-
3=Heating only (3-way
neous
valve)
0=Sealed Chamber
0=Sealed Chamber
with
with
combustion control
combustion control
(without fume
pressure switch)
cod. 3541D700 - Rev. 01 - 03/2018
Contents Description
Primary Exchanger type
selection
(b03=0)
No effect on adjustment
(b03=1)
No effect on adjustment
(b03=2)
b04
Primary Exchanger type
selection
~ 65W
(b03=3)
No effect on adjustment
(b03=4)
No effect on adjustment
(b03=5)
Relay card LC32
operation selection (b02=1)
No effect on adjustment
b05
(b02=2)
No effect on adjustment
(b02=3)
No effect on adjustment
(b02=4)
b06
Mains Voltage Frequency
Comfort burner on time
(b02=1)
No effect on adjustment
(b02=2)
b07
No effect on adjustment
(b02=3)
No effect on adjustment
(b02=4)
b08
Gas valve driver
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
FL 24 TCS
rameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting
occurs automatically after 2 minutes.

Service menu

The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 sub-
menus are available: press the Heating buttons to select, in increasing or decreasing or-
der, "tS", "In", "Hi" or "rE". "tS" means Transparent Parameters Menu, "In" means
Information Menu, "Hi" means History Menu: after selecting the submenu, press the Re-
set button again to access it; "rE" means History Menu Reset: see description.
"tS" - Transparent Parameters Menu
16 parameters indicated by the letter "P" are available: which are also modifiable from
Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
Contents Description
P01
Ignition ramp Offset
P02
Heating ramp
P03
Heating standby time
P04
Heating Post-Circulation
P05
Heating user max. set point
P06
Max. output in heating
Burner shutdown in hot water
production (b02=1)
P07
Burner shutdown in hot water
production (b02=2)
Hot water tank hysteresis
(b02=3)
Hot water tank hysteresis
(b02=4)
FL 24 TCS - 32 TCS
Range
Default
0=Flat
1=Omega
0=Flat
2=--
--
0
--
0
0=Flat
1=Omega
0=Flat
2=--
--
0
--
0
0=External gas valve
1=System filling sole-
0=External gas valve
noid valve
2=Solar 3-way valve
--
0
--
0
--
0
0=50Hz
0=50Hz
1=60Hz
0-20 seconds
5 seconds
--
5
--
5
--
5
0 = Standard, 1
0=Standard
Range
Default
0-40
20
1-20°C/minute
5°C/minute
0-10 minutes
2 minutes
0-20 minutes
6 minutes
31-85°C
80°C
0-100%
100%
0=Fixed
1=Linked to set point
2=Solar (5)
0=Fixed
3=Solar (10)
4=Solar (20)
0=Fixed
1=Linked to set point
2=Solar (5)
0=Fixed
3=Solar (10)
4=Solar (20)
0-4°C
2°C
0-4°C
2°C
FL 24 TCS
0=Flat
0
0=50Hz
5
0=Standard
FL 24 TCS
20
5°C/minute
2 minutes
6 minutes
80°C
100%
2°C

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Fl 32 tcs