Ariston 3318884 Instrucciones De Instalacion Y Uso página 39

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
- Install the Ariston Multifunctional Kit
- Install the Ariston Net gateway and link to the heating system through the Bus
BridgeNet connection
THERMOSTAT
TA1
TA2
5.2 Installation Ariston Sensys
The following procedure has to be made in order to install the thermoregulation
accessory supplied in the Ariston Net package and to replace an old thermostat
that may be already in the dwelling.
Positioning
The device detects the room temperature, therefore several factors should be ta-
ken into account when choosing an installation position. Keep it away from sources
of heat (radiators, sunlight, fi replaces, etc.) and from draughts, doorways and win-
dows which could aff ect the temperature measurement. We recommend to install it
approximately 1.50 metres above the fl oor level.
fi g.7
GATEWAY
SENSYS
BUS
GB
fi g.8
MULTIFUNCTIONAL
KIT
\ 39

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3318886

Tabla de contenido