Descargar Imprimir esta página

TESY 1005 Manual De Instrucciones página 4

Ocultar thumbs Ver también para 1005:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
OPERATION
EN
Turning-on
Put the plug into the socket, turn thermostat knob
clockwise and turn the appliance on as follows:
Only button (I) is turned-on – light heating –
MIN (W);
Only button (II) is turned-on – medium heating –
MED (W);
Both buttons are turned-on – intense heating –
MAX (W);
Power values of the corresponding levels (MIN(W),
MED(W), MAX(W)) are shown in table.
Model
MAX(W)
1005
1006
1506
1507
1508
2008
2009
2010
2011
2012
2510
2511
2512
2513
2514
3012
3013
3014
To turn off the appliance turn off the two buttons and
take the plug out of the socket outlet.
Thermoregulator adjustment
Power switch and thermoregulator should be set to
maximum position until the desired room temperature
is reached. Then turn thermoregulator switch in the
opposite direction till red light indicator goes down.
Thermoregulator may stay in that position after that.
Immediately after room temperature falls below
thermoregulator value thermal switches are turned on
automatically until set temperature is reached. In that
way room temperature is steady with minimum energy
consumption.
If you want to prevent temperature fall in the room
below 0 degrees Centigrade adjust thermostat switch in
its initial position and turn on the two power buttons.
4
Usage and Storage Instructions
MED(W)
1000 W
600 W
1000 W
600 W
1500 W
900 W
1500 W
900 W
1500 W
900 W
2000 W
1200 W
2000 W
1200 W
2000 W
1200 W
2000 W
1200 W
2000 W
1200 W
2500 W
1500 W
2500 W
1500 W
2500 W
1500 W
2500 W
1500 W
2500 W
1500 W
3000 W
1800 W
3000 W
1800 W
3000 W
1800 W
24-hours timer models ("T")
Adjust the heating period in the following consequence:
Set the clock to the correct
time. If it is 10 o'clock turn the
figures dial so that the mark is
positioned to the figure of 10.
Turn the figures dial only in the direction indicated
with arrows! Adjust the period of operation of the
appliance by pushing black keys to the center – every one
of them corresponds to 15 minutes period. Sector of the
MIN(W)
pushed keys will correspond to the period of operation of
the radiator in automatic mode every day.
400 W
400 W
600 W
Important : Plug should always be connected to the
600 W
socket outlet!
600 W
800 W
In order to change programmable period of
800 W
automatic operation turn black keys backwards and
800 W
adjust new periods of operation.
800 W
If you do not want the appliance to operate in
800 W
programmable mode push all black keys to the
1000 W
center of the figures dial. To turn off the radiator in
1000 W
that case you have to pull the plug out of the socket.
1000 W
In that way unnecessary operation of the timer is
1000 W
avoided.
1000 W
Thermal fan models ("V")
1200 W
1200 W
Models equipped with a 500W thermal fan offer
faster achievement of desired temperature and better
1200 W
ventilation in the room. Thermal fan may function
separately or together with oil-filled radiator. Thermal
fan is positioned in the bottom part of the front panel
of the radiator and is turned on by a switch positioned
in that part of the panel. Cold air is sucked through the
grating in the front part of the front panel and hot air is
released in the room through the grating positioned in
the bottom side part of the radiator panel. Desired room
temperature with thermal fan operation is adjusted by
thermoregulator of the radiator in the above mentioned
manner. For the normal operation of the thermal fan
it is necessary that air passes unobstructedly through
inlet and outlet grating. Electrical device is intended
for domestic use in premises with low level of dust
pollution. Dust is accumulated after certain period
of operation. In is necessary to check periodically
level of pollution and if needed to consult the service
organization for cleaning.
EN

Publicidad

loading