Count mode SUBTRACT
Outputs 1, 3 and 4 active when
count status < preset values 1, 3
and 4
Output 2 active when
count status < 0
Reset to preset 2
Count mode ADDING with
automatic reset
Outputs 1, 3 and 4 active when
count status > preset values 1, 3
and 4
Output 2 (timed signal) active
when count status = preset value 2
Automatic reset to zero when
count status = preset value 2
Reset to zero
Count mode SUBTRACTING
with automatic reset
Outputs 1, 3 and 4 active when
count status < preset value 1, 3
and 4
Output 2 (timed signal) active
when count status = 0
Automatic reset to preset 2 when
count status = 0
Reset to preset 2
Count mode ADDING with
automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset 2
Output 3 active when main
counter > preset value 3
Batch counter counts the number
of automatic repetitions of preset 2
Output 1 resp. 4 active when
batch counter > preset 1 resp. 4
Manual reset sets both counters
to zero.
Electrical reset only sets the
main counter to zero.
Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Output 3 active when main
counter > preset value 3
Total counter counts all the count
pulses from the main counter
Output 1 resp. 4 active when
total counter > preset value 1
www.kuebler.com
resp. 4
Manual Reset sets both counters
to zero
Electrical reset only sets the
main counter to zero
7.8.4.3 Submenu for configuration
Submenu for matching the input
pulses and display
Multiplication factor
Multiplication factor can be
programmed from 00.0001 to
99.9999. The setting 00.0000 will
not be accepted
Division factor
Division factor can be
programmed from 01.0000 to
99.9999. The setting <01.0000
will not be accepted
Decimal point setting
Decimal point (only optical
function)
0
0.0
0.00
0.000
0.0000
0.00000
Set value
Set value can be programmed
from -999999 to 999999
A previously programmed
decimal point will be displayed
Display colour (for device 6.924.x103.xxC)
Display colour
upper line
lower line
Display colour
upper line
lower line
7.8.4.4 Submenu for reset mode
Setting the reset mode
Manual reset (with red key) and
electrical reset (reset input)
no decimal place
1 decimal place
2 decimal places
3 decimal places
4 decimal places
5 decimal places
red
red
red
green
Seite 9