Kübler CODIX 924-4 Manual Del Usuario página 43

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Display
LCD positive or negative,
backlit
2 x 6-digit
Digit height
upper line
lower line
special characters
Overload/
Blinking, 1 s
Underload
Counter loses up to 1 decade
no pulses
Data retention
> 10 years, EEPROM
Operation
8 keys
Count frequency max. 50 kHz (see section 13.
frequencies typ.)
Response time of the outputs:
Relays
Add/Sub
With automatic repeat
A/B ; (A-B)/A
Frequency range
0.01 Hz to 50 kHz (see
section 13. frequencies typ.)
Measuring
76.3 Hz Time interval
principle
(period measurement)
> 76.3 Hz Gate time
Gate time approx.13.1 ms
Measuring error
< 0.1% per channel
Response time of the outputs:
1-channel operation < 110 ms @ 40 kHz
< 170 ms @ 50 kHz
2-channel operation < 200 ms @ 40 kHz
< 300 ms @ 50 kHz
Seconds
Minutes
Hours
h.min.s
Min. time measurable
Measuring error
Response time of the outputs:
Relays
Polarity:
programmable NPN/PNP
for all inputs in common
Input resistance
5 k
Pulse shape
any
www.kuebler.com
9 mm
7 mm
2 mm
< 14 ms
< 11 ms
< 38 ms
0.001 s ... 999 999 s
0.001 min ... 999 999 min
0.001 h .. 999 999 h
00h.00min.01s ...
99h.59min.59s
500 s
< 50 ppm
< 14 ms
Switching level with AC supply:
HTL level
Low:
High:
5V level
Low:
High:
Switching level with DC supply:
HTL level
Low:
High:
5V level
Low:
High:
Minimum pulse length of the Reset input:
Minimum pulse length of the Control inputs:10 ms
Output 1
Relay with make contact
programmable as NC or NO
Switching voltage
max. 250 VAC/ 110 VDC
Switching current
max. 3 A AC/ V DC
min. 30 mA DC
Switching capacity
max. 750 VA / 90 W
Mechanical service life (switching cycles)
N° of switching cycles at 3 A/ 250 V AC
N° of switching cycles at 3 A/ 30 V DC
Output 2
Relay with changeover contact
Switching voltage
max. 250 VAC/ 150 VDC
Switching current
max. 3 A AC/ A DC
min. 30 mA DC
Switching capacity
max. 750 VA/ 90 W
Mechanical service life (switching cycles)
N° of switching cycles at 3 A/ 250 V AC
N° of switching cycles at 3 A/ 30 V DC
Output 3
Relay with make contact
Switching voltage
max. 125 VAC/ 110 VDC
Switching current
max. 1 A AC/ 1 A DC
min. 1 mA AC/DC
Switching capacity
max. 62.5 VA/ 30 W
Mechanical service life (switching cycles)
N° of switching cycles at 0.5 A/ 125 V AC
N° of switching cycles at 1 A/ 30 V DC
Output 4
Relay with changeover contact
Switching voltage
max. 125 VAC/ 110 VDC
Switching current
max. 1 A AC/ 1 A DC
min. 1 mA AC/DC
Switching capacity
max. 62.5 VA/ 30 W
Mechanical service life (switching cycles)
N° of switching cycles at 0,5 A/ 125 V AC
N° of switching cycles at 1 A/ 30 V DC
0 ... 4 VDC
12 ... 30 VDC
0 ... 2VDC
3,5 ... 30 VDC
0 ... 0,2 x UB
0,6 x UB ... 30 VDC
0 ... 2 VDC
3,5 ... 30 VDC
1 ms
7
2x10
5
1x10
5
1x10
6
20x10
4
5x10
4
5x10
7
5x10
5
1x10
5
1x10
7
5x10
5
1x10
5
1x10
Seite 17

Publicidad

Tabla de contenido
loading

Tabla de contenido