- EN -
Installation and connection
Operation with pool water or salt water
• For operation with pool water or salt water, the following limits must be adhered to:
Type
pH value
Free chlorine
Bound chlorine
Chloride content
Salt content
Water temperature
• Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the guarantee.
Distances to be adhered to
B
• Minimum safety distance between the unit and the water: 2 m.
• Allow sufficient space for carrying out maintenance work.
– Ensure that there is space of at least double the width of the casing for removing the unit head.
Solo operation
C
• Only install the unit in the permitted positions to ensure fault-free operation.
• Take the required distances into consideration. (→ Distances to be adhered to)
• Use suitable fastening material for the type of ground. Ensure that the fastening means securely hold the unit. Take
the weight of the unit into consideration. (→ Technical data)
• Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be installed below the water level.
This allows the water supply to be shut off for maintenance work.
Connecting the inlet
Use hoses that are suitable for a pressure of at least 1 bar.
Recommended combinations for using the hose connector.
Inlet
50 mm (2 ")
38 mm (1½ ")
38 mm (1½ ")
50 mm (2 ")
How to proceed:
D
1. Push the inlet nozzle into the inlet.
– The inlet nozzle is only necessary for a flow rate < 10000 l/h to ensure unimpaired rotation of the cleaning rotor.
2. Screw the hose connector with union nut and seal onto the inlet.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
Connecting the outlet
How to proceed:
E
1. Screw the adapter with seal onto the outlet and hand tighten.
2. Screw the stepped hose adapter with union nut and seal onto the adapter.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
4. Screw the cover cap with flat seal onto the outlet.
– The cover cap has to close the outlet opposite the inlet so that the main flow of water is guided along the UVC
lamps and is exposed to the UV radiation for as long as possible.
24
Outlet 1
50 mm (2 ")
38 mm (1½ ")
38 mm (1½ ")
38 mm (1½ ")
Pool water
7.2 ... 7.6
0.3 ... 0.6mg/l
< 0.2 mg/l
< 200 mg/l
–
+4 ... +30°C
Outlet 2
(opposite the inlet)
closed
closed
38 mm (1½ ")
38 mm (1½ ")
Salt water
7.5 ... 8.5
< 0.3mg/l
–
–
< 3.5 %
+4 ... +25°C
Required accessories
–
–
For outlet 2, a 38 mm (1½ ") hose con-
nector with 38 mm (1½ ") union nut