System Messages - Oase Bitron Eco 120W Instrucciones De Uso

Ocultar thumbs Ver también para Bitron Eco 120W:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
- EN -

System messages

The system messages are indicated in the display. If there are several system messages pending at the same time,
the oldest message is always displayed.
• The 4-digit system message is indicated in the display by two groups of two digits in succession.
• As soon as the cause has been eliminated, the system message is automatically extinguished.
System message
Er11
Unit has switched off.
Er66
Unit has switched off.
Er67
ErL1
Bitron Eco 180W
ErL2
Bitron Eco 240W
Temperature value
88
flashing
Lo
Commissioning/start-up
N O T E
If the water flow is suddenly interrupted downstream of the outlet (e.g. with a slide valve), this can lead to a
brief increase of pressure of more than 1 bar (water hammer). Possible consequences: The unit may be da-
maged.
• Switching off: First switch off the pump, then close the slide valve. If the unit is operated in a filter system,
first take the filter system out of operation.
• Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a filter system,
start up the filter system last.
• Install the slide valve upstream of the inlet.
N O T E
New filters take approx. 3 to 4 weeks before the bacteria in the unit are fully established. During this time – or
at a water temperature of <10 °C – the filter may overflow. In this case the filter does not need to be cleaned.
• When using filter starter, medicines or pond water treatments, leave the UVC clarifying unit switched off for
at least 36 hours so as not to impair their efficacy.
Order of starting up steps
N O T E
The unit is switched off in the delivery state. OFF is indicated on the display.
• In the case of new pond installations, do not start the UV irradiation until at least 36 hours after set-up to
ensure that a stable pond biology can develop as quickly as possible.
• Switch on the pump.
• Check all connections for leaks.
• Connect the unit to the power supply.
– The unit switches on with the last selected operating mode.
– Switch on the unit if necessary. (→ Switching ON/OFF)
28
Cause
− Unit head removed.
− Unit head is not correctly seated in the
casing.
Unit overheated.
Unit temperature has been exceeded five time
in succession.
UVC lamp "L1a" and/or "L1b" defective.
UVC lamp "L2a" defective
UVC lamp "L2a" and/or "L2b" defective
Water temperature < 4 °C
Ambient temperature < -9 °C
Remedy
Insert unit head into the casing, close with the engagement hook
and secure with screw.
− Protect unit from direct sun radiation.
− Ensure that water can continuously flow through the casing.
− After cooling down, the unit automatically switches on again
and activates the last selected operating mode.
− Eliminate the cause of overheating (e.g. direct sun radiation,
no water flow).
− Keep the button pressed for six seconds.
− Replacing a defective UVC lamp (→ Maintenance and
cleaning)
− ErL1 is not extinguished: Contact the OASE service.
− Replacing a defective UVC lamp (→ Maintenance and
cleaning)
− ErL2 is not extinguished: Contact the OASE service.
− Replacing a defective UVC lamp (→ Maintenance and
cleaning)
− ErL2 is not extinguished: Contact the OASE service.
Ensure water temperatures of at least 4 °C or take the unit out of
operation (→ Storage/overwintering)
Temperature display out of operation, operation is not practical.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bitron eco 180wBitron eco 240w

Tabla de contenido