Troubleshooting schedule

Troubleshooting the battery and/or the battery charger during charging.
Battery
LED display
Green activate LED flashing.
Error LED flashes.
Error LED is lit

Battery charger

LED display
Error LED flashes.
Error LED is lit

Control panel

Keypad
Error LED flashing
94 – English
MAINTENANCE
Possible faults
Low battery voltage.
The battery is discharged.
Temperature deviation.
Over voltage.
Cell difference too much.
Possible faults
Temperature deviation.
Possible faults
Overload.
Motor control has overheated.
The blade is blocked.
If engine speed drops below a critical
value, the motor will stop.
Possible action
Charge the battery.
Charge the battery.
Use the battery in surroundings
where temperatures are between
-10 °C and 40 °C.
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Remove the battery from the battery
charger. Wait 5 seconds and try again
to recharge the battery. If the problem
persists, contact an authorized
service workshop.
Contact an authorised service
workshop.
Possible action
Use the battery charger only when the
surrounding temperature is between 5
°C and 40 °C.
Contact an authorised service
workshop.
Possible action
Prevent unintentional start by turning
the safety key to "0", removing the
battery and waiting at least 5 seconds.
Make sure the blade can rotate freely.
If the problem persists, contact an
authorized servicing dealer for further
information.