Cooling (Optional); Cooling Cycle Setting - Lotus PFDG Serie Manual De Instruciones Para El Uso

Marmita a gas directa, marmita a gas indirecta, marmita eléctrica indirecta, marmita a vapor indirecta
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The models equipped with optional PARI00... can chill down the food thanks to
cold water filling of the double-jacket.
2.4.1

COOLING CYCLE SETTING

Note: the cooling cycle is available only if a cooking time has been set.
After time and temperature setting (see .2.2.3 and 2.2.5/6) keep pressed
for 2 sec. (
key led start lighting).
− Top display shows the temperature SETPOINT value i.e. (H65)
− by
Note : see HOLDING paragraph:
If the temperature rate is in ° F holding function ( H) is not available la funzione.
Top display will show the cooling temperature SETPOINT. I.e.:
− by
to confirm your choice press again
Top display (8) shows the set value C10 and the cooking SETPOINT.
ATTENTION:
The cooling temperature SETPOINT must be higher than cooling
water temperature + (5÷10° C) .
The cooling temperature SETPOINT must be lower than cooking
temperature SETPOINT. Otherwise the kettle starts the jacket
emptying after cooking cycle.
− Turning off the equipment the SETPOINT remains on memory.
Cooling cycle must be activated any cooking.
Instruction manual and use
Kettles PF..

2.4. COOLING (OPTIONAL)

select cooling cycle (C10) .
C = Cooling
10 = cooling temperature SETPOINT ° C
choose the temperature (range 0÷99° C)
or wait 4 seconds
GB-PF-DU-02
12 di 18
Pag

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pfig seriePfie seriePfiv serie