Power supply voltage
Absorption
Max. CT input cable length
Inputs
Indications
Terminals
Positioning
Approvals
Operating temperature
Storage temperature
Relative air humidity
Accessories included
Weight
Dimensions
*With access allowed only for support or servicing by qualifi ed personnel
Terminal
6

TECHNICAL CHARACTERISTICS

CONNECTION TERMINALS

-
+
D
V- IT
L N
24 Vdc ± 5%
35 mA
2 m
1 for connection of the CT current
transformer (supplied), ideal for single-
phase lines up to 10 kW.
1 for line voltage (230 Vac)
1 bus status LED: when fl ashing,
indicates data transmission via bus
removable
*On a DIN rail on a dedicated control
panel or in junction boxes
CE
0° to 50°C
-10° to +70°C
5 to 95% with no condensation
CT current transformer
70 g, not including CT and packaging
35x90x58 mm (3 DIN modules)
Function
BUS power supply negative
BUS power supply +24 Vdc
BUS data line
Input for non-polarised toroid connection
Line voltage connection