Pre-alarm: pre-alarm vocal messages or series of "Beeps". Sirenya sirens signals > signal by intermittent acoustic sounds
Outdoor alarm: external alarm vocal message or series of "Beeps" . Sirenya siren works in "outdoor alarm" mode.
General alarm: activation of control panel siren and of all sirens (see instructions of the sirens used) provided in the system
Panic alarm with system partially armed or disarmed: no control unit alarm, but activation of all wireless sirens provided
Robbery alarm: no control unit alarm, no sirens, but just activation of the "robbery" telephone calls. This control can also be used to
call for a doctor or request other assistance by telephone.
Technological alarm: intermittent acoustic signal from the control unit for 15 seconds.
Tampering alarm with system partially armed or disarmed: intermittent acoustic signal from the control unit for 3 minutes.
Tampering alarm with system armed: like general alarm.
Attention! Consider the following aspects:
a) In any case disarming the system will silence the sirens.
b) During each arming period of zones A, B, C only three alarms are accepted by each detector in order to avoid that a defective detector
becomes a public disturbance. The count re-starts at every arming.
2.2) Bidirectional telephone part - Telephone calls
In the installation phase the relevant messages must be recorded/written and connected to telephone numbers to call in the event of alarms: for
example the ALARM will be connected to user, family or friend's numbers, numbers of intervention forces. It is useless to connect the installer's
number to the alarm calls, while it is useful to connect it to the "low battery" calls. The telephone calls to the Police Force require previous
approval, ruled differently from place to place.
PSTN fixed network: all control units allow the transmission of 6 vocal messages, linked to 6 specific events that are transmitted on the PSTN
line network to up to 63 users whose numbers have been appropriately programmed.
GSM mobile network: the 5500-5501 model control units, with GSM module, transmit the same messages onto the GSM network, but the
relative SMS is sent before the messages, except if programmed differently, useful if no-one answers. A further 11 SMSs programmed at the
factory and with a technical content are transmitted following an event. Any of the 63 telephone numbers available can be enabled to receive
one or more vocal and/or SMS messages, according to specific requirements.
2.2.1) VOCAL/SMS MESSAGES TO RECORD/WRITE: factory connection envisions 6 main events
ALARM ZONES A,B,C: intrusion alarm message generated by detectors programmed on any zone A,B,C. It is possible to select the zones
so as not to transmit the message, for example, outdoor alarm coming from zone A, while the alarms from zones B and C will be
transmitted.
TAMPERING: alarm message always active, generated by tampering with one or more system devices .
24H PANIC: alarm message always active, generated by a manual command, for example yellow key on the remote control.
24H ROBBERY: alarm message always active, generated by a manual command, for example yellow key on the remote control.
24H TECHNOLOGICAL: alarm message always active, generated by a technical alarms detector (smoke, water, gas etc.)
BATT. FLAT: alarm message always active, generated by a system component with low battery.
2.2.2) SMS PROGRAMMED IN THE FACTORY (MODELS 5500-5501 - Note: the messages 6, 7, 11 are only on the 5500 model)
1 = control unit battery flat: attention! The system will soon stop functioning!
2 = peripheral battery flat: attention! One or more detectors will cease to function shortly (days)!
3 = no supervision and/or presence of radio interference: check the events memory on return
4 = system armed: the message is sent only in response to arming via telephone from outdoors
5 = system disarmed: the message is sent only in response to disarming via telephone from outdoors
6 = 230V electric mains failure - the message is sent without network after the set time (SETTINGS)
7 = no GSM cover for more than 15 min.: the message starts on return of the GSM field
8 = no correct call on the PSTN line: check for interruption of the telephone line (PSTN network)
9 = periodic message of operating status of the control unit: cyclic message every so many hours/days (SETTINGS)
10 = SIM expiry warning message: program (SETTINGS) new expiry in case of pre-paid SIM
11 = 230V mains return: automatic message consequent to SMS 6
Identification: the correct vocal recording and writing of the "labels" of the various detectors in the programming phase allows the user to
receive all messages with the exact indication regarding the device of interest.
2.2.3) TELEPHONE CALLS TO SECURITY SERVICES: the control units contemplate digital protocols suitable for communication with the
security service control units. This protocol must be appropriately programmed with instructions that must be requested specifically.
2.2.4) REMOTE ASSISTANCE TELEPHONE CALLS: the control units can be enabled by the user to automatically connect with the
headquarters of the installer (if this service is provided by the installer) in order to perform interventions and system set up from a distance.
2.2.5) HOME AUTOMATION FUNCTIONS
A) Programmable clock: the control unit has a programmable clock for forced arming or other function.
B) Electric outputs (5500-5502 models only): two relays are available, which can be activated via telephone, for control of the electrical
charges of various nature.
C) Radio outputs: 16 commands via radio are available for local RX receivers, which can be activated from the control unit via telephone in
order to switch lights or other electric utilities on. These receivers can be also activated by remote control, via the keypad and the detectors.