Programming Hard-Wired Alarm Zones; Settings Menu: Detectors Exclusion - Relay Functions - SILENTRON SILENYA HT 5500 Manual Del Usaurio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.8.4) INTRUDER ALARM ZONES AND WIRED ADDITIONAL KEY (models 5500-5502)
ALARM GROUP A
↵ CONFIRM
WIRED INPUT 1
↵ DELAY
0 SEC
1 ↑
WIRED INPUTS
↵ ZONE (GROUPS) A ↓
KEY
ON
A B C
OFF
A B C
4.9) SETTINGS: in this part some particular functions of the control unit are programmed. Scroll the various functions using the ↑ ↓ keys
4.9.1) DETECTOR EXCLUSION
EXCL. SENSORS
↵ CONFIRM
EXCL. SENSORS
↵ CONFIRM
4.9.2) SETTING THE FUNCTIONS OF THE RELAYS R1 AND R2 (models 5500-5502)
R1 factory setting is ON-OFF (bistable switch), which switches after ON command and stops with OFF command of the internal clock or via
telephone. Switching via telephone predominates over the clock command. R2 factory setting is GENERAL ALARM: this relay cannot be
activated from the clock. R1 - R2 can be used in other ways as follows:
IMPULSIVE: switches for a time from 0 to 999 seconds following a telephone or internal clock command.
GENERAL ALARM: switches for the time set for alarms of any type excluding antiscanner.
TAMPERING: switches for 3 minutes in the case of a tampering alarm.
24H PANIC/ROBBERY/TECHNICAL: switches for 15 minutes in the case of a panic/robbery/ technical alarm
ANOMALY: switches for 15 seconds if the battery is flat (control unit and/or detectors), failed supervision, radio interference with system
armed (antiscanner) , no GSM field (model 5500).
ARM/DISARM: switches on arming and stops upon disarming (useful for connecting an on-off indicator light)
INP. DEL. : switches during the input relay set on one or more detectors (inlet time).
RELAY
SETTINGS
↵ CONFIRM
SILENTRON spa – 10139 – Via Sagra S.Michele 25 Torino - ITALIA
WIRED INPUTS
.
.
↵ CONFIRM
You can insert an alarm delay:
write delay in seconds (0-99)
WIRED INPUTS
↵ ZONE (GROUPS) A ↓
The key can switch on-off one or
more groups: choose the group
A,B,C by pressing 1,2,3,4,5,6
then insert write and vocal label
A 01
BEDROOM
↵ CONFIRM
EXCL. WIRED INPUTS
↵ CONFIRM
RELAY 1 SETTINGS ↑
↵ CONFIRM
WIRED INPUTS
↵ ZONE (GROUPS) A ↓
LABEL WIRED
BEDROOM (example)
Proceed in the same mode
2
for all 6 wired inputs
and 3 tamper inputs
E
S
C
Select the detector you want
to exclude by pressing ↑↓
Proceed as well as
EXCL. SENSORS
Choose the described
function by ↑↓ and insert
timing if requested
COPYRIGHT SILENTRON DS5500/1/2/3XC100120GM
1 ↑
You can join the input 1 to the
alarm groups (A=1, B=2, C=3).
Proceed as well as
1
"Detector Programming"
just to end of RECORD
E
EXTERNAL KEY
S
↵ CONFIRM
C
Select (↑↓) INCLUDED or
EXCLUDED and confirm ↵
The excluded sensors will
not give any alarm.
EXCL. WIRED INPUTS
E
S
C
↵ CONFIRM
Example:
GENERAL ALARM
T: 180 SEC.
E
S
C
E
S
C
E
S
C
33

Publicidad

Tabla de contenido
loading

Productos relacionados para SILENTRON SILENYA HT 5500

Este manual también es adecuado para:

Silenya ht 5501Silenya ht 5502Silenya ht 5503Silenya ht 5500

Tabla de contenido