Installation
1
Install and Anchor Unit
Rough-in of plumbing lines and wall braces must be
completed before unit can be properly installed.
A
Remove Access panel and with
the help of another person, place
unit in position against wall .
B
Ensure unit is level, shimming floor unit if
necessary . Mark the wall anchor locations .
2
Connect Water Supply to Valve Assembly
Connect stops to hot and cold water supply .
A
Connect one end of each supply hose to a
stop and the other end to the hot and cold
inlets of the Navigator
STOP!!! If installing optional Shroud/Slip Ring or Towel Dispensers,
complete those installations before proceeding to Step 3 (see page 7).
Bradley • 215-1070 Rev. K; ECN 14-00-007
Water Supply
Gang Valve
Assembly
TMV .
®
OPTIONAL TEMPERED LINE CONNECTION: Connect one
B
end of the supply hose to the stop and the other end to the
tempered line adapter in the gang valve assembly .
SN2004/AST4, SN2004/AST4-F, SN2024/AST4
Install suitable wall anchors (supplied
C
by installer) for 3/8" bolts at the marked
locations . Secure unit to wall .
Red Tube
(to Aerator)
Green Tube
(to Aerator)
Black Tube
(to Aerator)
Yellow Tube
(to Aerator)
Navigator TMV
Cold Supply Inlet
8/18/2014
Water Supply
Gang Valve
Assembly
OPTIONAL
Tempered
Line Adapter
Assembly
(S39-804)
Braided
Hose
Stop Valve
Hot Supply Inlet
5