• 125,000 - 170,000 Btu/Hr (36.6 - 49.8 kW)
• Propane/LP Fuel
• Gas Supply Pressure to Regulator
Max - Bottle Pressure, Min - 5 psig (34.5 kPa)
• Gas Supply Pressure Regulator out
28" WC (6.97 kPa)
• Electrical Input - 115V, 60 Hz, 1Ø, 3a
• Direct Spark Ignition, interrupted type
• Primary Flame Control - Solid State
• High Temperature Control -
• Minimum Ambient Temp. Rating - 0°F (-17.8°C)
• Fuel Consumption - 5.8 - 7.9 lbs/hr (2.6 - 3.6 kg/hr)
• Fuel Orifice Port No. - 18
• Fuel Orifice Port Size - 0.80 mm
• Heated Air Output - 450 CFM (12.74 cu m/m)
Gas
Valve
Chassis
Ground
Motor
Thermostat
Line Cord
Chassis
Ground
10
SPECIFICATIONS
240°F (116°C)

WIRING DIAGRAM

CONNECTION DIAGRAM
Red
Green
White
Red
Red
Black
If any original wiring as supplied with the heater must
be replaced, it must be replaced with type AWG 105° C
Green
wire or its equivalent except as indicated
(*Type SF2-200. **SGI-250° C)
www.desatech.com
High Limit
Switch
Red
Black
White
Red
Chassis
Ground
Spark Plug
Line
Neut
Valve
Ground
Flame Control
113959-01B