NORMAL
Con funzionamento a uomo
presente se le fotocellule o le
coste sono guaste. Conforme alle
normative in vigore.
Avec travail avec homme present,
dans le cas de panne de sécurité.
Conforme aux Normes en vigueur.
With functioning in dead man mode when
the safety devices are failing. According
to current European Norms.
Mit arbeit im mannsbeisein im fall
eines ausfalls der Sicherheiten. In
Übereinstimmung mit der aktuellen
Normen.
Con funcionamiento a hombre presente
en caso de averías con los accesorios de
seguridad. En conformidad a las Normas
en vigor.
ITALIANO pag. 05 / FRANÇAIS pag. 15 / ENGLISH page 25 / DEUTSCH pag. 35 / ESPAÑOL pag. 45
Operatore
Alimentazione
Operateur
Alimentation
Operator
Power Supply
Torantrieb
Stromspannung
Operador
Alimentacion
NORMAL
230V 50Hz
con / avec / with / mit
PARK 230V
BARRIERA IRREVERSIBILE PER IL CONTROLLO DEL
TRAFFICO VEICOLARE
BARRIÈRE IRRÉVERSIBLE POUR LE CONTRÔLE DU
TRAFIC VÉHICULAIRE
IRREVERSIBLE BARRIER FOR VEHICULAR TRAFFIC
CONTROL
SELBSTHEMMENDE SCHRANKE ZUR
VERKEHRSSTEUERUNG
BARRERA IRREVERSIBLE PARA CONTROL DE
TRÁFICO VEHICULAR
Lunghezza max asta
Longueur maxi de la lisse
Max. boom lenght
Max. Baumlänge
Longitud máxima de la asta
6 / 7 m
Codice
Code
Code
Code
Codigo
AA50000

Publicidad

Tabla de contenido
loading

Resumen de contenidos para RIB NORMAL RARK 230V

  • Página 1 NORMAL con / avec / with / mit PARK 230V Con funzionamento a uomo presente se le fotocellule o le coste sono guaste. Conforme alle normative in vigore. Avec travail avec homme present, BARRIERA IRREVERSIBILE PER IL CONTROLLO DEL dans le cas de panne de sécurité. TRAFFICO VEICOLARE Conforme aux Normes en vigueur.
  • Página 2 (par exemple en l’installant dans un cadre fermé à clé). 2° - Per la sezione ed il tipo dei cavi la RIB consiglia di utilizzare un cavo di tipo 2° - Pour la section et le type des câbles, la RIB conseille d’utiliser un câble de type H05RN-F con sezione minima di 1,5 mm 2 e comunque di attenersi alla norma IEC H05RN-F ayant une section minimum de 1,5 mm 2 et de toute façon s’en tenir...
  • Página 3 (for example by installing inside a locked board). einer ungewollten Schließung (z.B. wenn sie in einer abgeschlossenen Schalttafel 2° - For the section and the type of the cables, RIB advices to use a cable of the installiert ist).
  • Página 4: Conservar Cuidadosamente Estas Instrucciones

    (por ejemplo instalándolo dentro de un panel cerrado a llave). 2° - Para la sección y el tipo de los cables, la RIB aconseja utilizar cables de tipo H05RN-F con sección mínima de 1,5 mm 2 e igualmente atenerse a la norma IEC 364 y a las normas de instalación del propio país.
  • Página 5 LAYOUT IMPIANTO Barriera NORMAL - Fotocellule di sicurezza - Colonnina portafotocellula zincata - Fotocosta - Sensore magnetico - Selettore a chiave - Antenna radio Misure in mm - Pulsante d’emergenza CARATTERISTICHE TECNICHE CARATTERISTICHE NORMAL TECNICHE Motoriduttore irreversibile ambidestro utilizzato per movimentare aste lunghe fino a 6-7 m. Lunghezza max.
  • Página 6: Regolazione Finecorsa

    INSTALLAZIONE NORMAL MONTAGGIO DELLA NORMAL Componenti da installare secondo la norma EN12453 Dopo aver cementato il basamento di fissaggio nella posizione da Voi ritenuta ideale, USO DELLA CHIUSURA procedete nel fissaggio della NORMAL utilizzando i dadi in dotazione e una chiave esagonale TIPO DI COMANDO Persone esperte Persone esperte...
  • Página 7: Sblocco Di Emergenza

    REGOLAZIONE MOLLA DI BILANCIAMENTO La barriera viene fornita con le molle di bilanciamento già registrate. In caso vengano aggiunti pesi all’asta (es. coste pneumatiche o a fotocellula) è necessario ribilanciare l’asta. Se l’asta durante il movimento di discesa tende a precipitare, agire sulle molle di bilanciamento. Per far ciò...
  • Página 8: Collegamenti Elettrici

    COLLEGAMENTI ELETTRICI PARK CRX cod. AC07063 CONDENSATORE MOTORE LAMPEGGIATORE ALIMENTAZIONE 230Vac 50 Hz ANTENNA CALZA PASSO PASSO BUZZER ANTENNA R=2K2 STOP CHIUDE APRE 1 APRE 2 OK CHIUDE 12 Vdc max 0,5A per ACCESSORI 12 Vdc max 0,5A per AUTOTEST PER COSTA COSTE FOTOCEL.
  • Página 9: Rele' E Comando Motore

    A - CONNESSIONI Alimentazione 230Vac 50/60Hz (120V/60Hz a richiesta) Comune dei contatti Contatto finecorsa che ferma la chiusura (NC) Contatto finecorsa che ferma l’apertura (NC) LSSC Non utilizzati LSSO Non utilizzati Contatto segnalazione presenza veicolo (NO) (solo in modalità PARK) PHOT.
  • Página 10 - La sbarra rimane ferma nel punto in cui è avvenuto il black-out 6 - Riposizionare DIP 1 su OFF e DIP 2 su OFF. DIP 11 7 - Fine procedura. per sbarra NORMAL PROCEDURA CANCELLAZIONE TOTALE CODICI RADIO DIP 12 La segnalazione si può...
  • Página 11 ANTENNA MODALITA’ NORMALE I tempi di pausa prima di avere la chiusura DIP 6 OFF automatica della sbarra vengono registrati durante la PASSO PASSO CALZA BUZZER programmazione dei tempi. ENTRATA R=2K2 ANTENNA STOP Il tempo di pausa massimo è di 5 minuti. CHIUDE Il tempo di pausa è...
  • Página 12: Caratteristiche Tecniche

    veicolo in ingresso (se non si vuole usufruire di questa funzione eseguire un ponticello tra La segnalazione dell’attivazione di questo funzionamento è data dal led di programmazione i morsetti Com e TLC). Solo la presenza di un veicolo consente l’apertura della sbarra in che lampeggia.
  • Página 13 OPTIONAL Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione. ASTA 6 m OTTAGONALE TELESCOPICA ASTA 7 m OTTAGONALE TELESCOPICA Asta 6 m ottagonale telescopica con mozzo L = 3+3 m. Asta 7 m ottagonale telescopica con mozzo L = 4+3 m. cod.
  • Página 14 PALETTO PENDULO PALETTO DI SUPPORTO SCHEDA OPZIONALE A 3 RELÉ PER LUCE BOX o ELETTROMAGNETE E GESTIONE SEMAFORO cod. ACQ9081 SENSORE A SPIRA MAGNETICA Per apertura con automezzi monocanale - 230 Vac cod. ACG9060 monocanale - 12÷24 Vac/dc cod. ACG9063 bicanale - 12÷24 Vac/dc cod.
  • Página 15: Caracteristiques Techniques

    SCHÉMA DÉTAILLÉ DE L’INSTALLATION Barrière NORMAL - Photocellules p/protection - Poteau zingué p/cellule - Fotocosta - Boucle magnetique - Selecteur - Antenne radio Mesures en mm - Arre d’urgence CARACTERISTIQUES TECHNIQUES CARACTERISTIQUES NORMAL TECHNIQUES Motoréducteur irréversible «ambidextre» utilisé pour actionner des lisses pouvant atteindre jusqu’à Longueur maxi de la lisse 6-7 mode long.
  • Página 16 INSTALLATION NORMAL MONTAGE DE LA NORMAL Parties à installer conformément à la norme EN12453 Après avoir cémenté la plaque de fixation à l’endroit voulu, procéder à la fixation de la NORMAL USAGE DE LA FERMETURE en se servant des écrous en dotation et d’une clé n° 19 à 6 pans. TYPE DE Personnes expertes (au Personnes expertes...
  • Página 17 RÉGLAGE DES RESSORTS D’ÉQUILIBRAGE Lorsque la barrière est livrée, les ressorts d’équilibrage sont déjà réglés. En cas de rajout de poids à la lisse (ex. cordons pneumatiques ou avec photocellule), il est indispensable de rééquilibrer cette dernière. Si la lisse a tendance à tomber pendant le mouvement de descente, agir sur les ressorts d’équilibrage.
  • Página 18: Branchements Électriques

    BRANCHEMENTS ÉLECTRIQUES PARK CRX code AC07063 CONDENSATEUR MOTEUR FEU CLIGNOTANT ALIMENTATION 230Vac 50 Hz ANTENNE ENVELOPPE PAS A PAS BUZZER ANTENNE R=2K2 STOP FERME OUVRE 1 OUVRE 2 OK FERME 12 Vdc max 0,5A pour ACCESSOIRES 12 Vdc max 0,5A pour AUTOTEST POUR CORDON DE SICURITE CORD.
  • Página 19 A - BRANCHEMENTS Alimentation 230 Vca 50/60Hz (120V/60Hz sur demande) Emplacement des contacts Contact fin de course arrêtant la fermeture (NC) Contact fin de course arrêtant l’ouverture (NC) LSSC Pas utilisés LSSO Pas utilisés Contact de signalement de la présence d’un véhicule (NO) (uniquement en mode PARK) PHOT.
  • Página 20 DIP 9 imparties. Si le téléguidage est correctement mémorisé, la DEL DL9 (verte) clignote. - Activation TEST de contrôle barre palpeuse 4 - Le temps de programmation des codes se renouvelle automatiquement de façon à - Désactivation du TEST de contrôle barre palpeuse permettre la mémorisation du téléguidage suivant.
  • Página 21: Télécommande

    TÉLÉCOMMANDE ANTENNE MODE NORMAL DIP4 OFF => Effectue une commande cyclique des DIP 6 OFF PAS A PAS ENVELOPPE commandes ouvre-stop-ferme-stop- BUZZER ENTRÉE R=2K2 ANTENNE STOP ouvre-etc. DIP4 ON => Procède à l’ouverture lorsque la lisse FERME est fermée. S’il est actionné lors de OUVRE 1 l’ouverture, il ne produit aucun effet.
  • Página 22: Voyant De Signalisation Barrière Ouverte (Com-Signal)

    FONCTIONNEMENT APRÈS UNE COUPURE present. La signalisation de l’activation de cette opération est donnée par la LED de programmation Avec DIP 10 sur OFF => En l’absence de tension de réseau, la lisse reste fermée ou qui clignote. s’arrête si elle est en mouvement. Lorsque le courant de réseau Avec cette opération est autorisée l’ouverture ou fermeture seulement en appuyant sur les est à...
  • Página 23 OPTIONS Pour les branchements et les données techniques des accessoires, se conformer aux livrets d’instruction correspondants. TIGE DE 6 m OCTOGONALE TELESCOPIQUE TIGE DE 7 m OCTOGONALE TELESCOPIQUE Tige de 6 m octogonale télescopique avec moyeu L = 3+3 m. Tige de 7 m octogonale télescopique avec moyeu L = 4+3 m.
  • Página 24 FOURCHE ESCAMOTABLE PIEU DE SUPPORT CARTE EN OPTION À 3 RELAIS POUR BOîTE DE LUMIÈRE OU ÉLECTROAIMANT ET GESTION DES FEUX code ACQ9081 CAPTEUR À SPIRE MAGNÉTIQUE Pour ouverture avec véhicules automobiles monocanal - 230 Vac code ACG9060 monocanal - 12÷24 Vac/dc code ACG9063 deux canaux - 12÷24 Vac/dc code ACG9064...
  • Página 25: System Lay-Out

    SYSTEM LAY-OUT 181,10” 2755,90” 118,11” NORMAL barrier Measurements in mm/inch - Photoelectric cells - Galvanized column for P.E. cells - Fotocosta - Magnetic loop TECHNICAL - Key selector NORMAL DATA - Tuned aerial - Emergency button Max. boom lenght Opening time Max.
  • Página 26 NORMAL INSTALLATION ASSEMBLING THE NORMAL BARRIER Parts to install meeting the EN 12453 standard After having cemented the fixing base in the position you prefer, fix the NORMAL unit, using USE OF THE SHUTTER the nuts supplied and a setscrew wrench n. 19. COMMAND TYPE Skilled persons Skilled persons...
  • Página 27: Emergency Release

    ADJUSTING THE BALANCING SPRING The barrier is supplied with its balancing springs already adjusted. If extra weights are added to the barrier boom (e.g. pneumatic or photocell-type safety strips), you need to balance the boom again. If the boom tends to drop quickly when it moves down, modify the balancing springs.
  • Página 28 ELECTRIC CONNECTIONS PARK CRX code AC07063 CAPACITOR MOTOR BLINKER POWER SUPPLY 230Vac 50 Hz COAX K BUTTON BUZZER R=2K2 STOP CLOSE OPEN 1 OPEN 2 OK CLOSE 12 Vdc max 0,5A for ACCESSORY SUPPLY 12 Vdc max 0,5A for AUTOTEST EDGE EDGE PHOTO...
  • Página 29 A - CONTROL PANEL FEATURES Main power supply 230Vac 50/60Hz upon request) Common contact Closing limit switch contact (NC) Opening limit switch contact (NC) LSSC Not used LSSO Not used Vehicle presence signal (NO) (only when switched to PARK mode) PHOT.
  • Página 30 DL1 - Programming activated (red) DL2 - Stop contact (red) DL3 - Barrier opening (green) DL4 - Barrier closing (red) FUNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF) DL5 - Photocells contact (red) ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED. DL6 - Safety strip contact (red) Make sure that any other type of command accessories (e.g.
  • Página 31 STANDARD OPERATION AERIAL DIP 6 OFF K BUTTON COAX BUZZER ENTRY R=2K2 STOP CLOSE OPEN 1 EDGE 12 Vdc max 0,5A for ACCESSORY SUPPLY 12 Vdc max 0,5A for AUTOTEST EDGE TIMER MAGNETIC LOOP TO EXIT OPERATING IN PARK MODE (DIP6 ON) PARK OPERATION AERIAL DIP 6 ON...
  • Página 32 entrance. Whereas the OPEN2 command is enabled only if the TLC input is opened, absence Once the failing safety device is repaired, in automatic after 1 second, all standard of a vehicle at the entrance. commands that were selected, such as step by step, automatic mode, radio commands and If in PARK MODE the TLC input is useless.
  • Página 33: Base Plate

    ACCESSORIES For the connections and the technical data of the optional equipments follow the relevant handbooks. TELESCOPIC OCTAGONAL BOOM ARM, 6 m TELESCOPIC OCTAGONAL BOOM ARM, 7 m Telescopic octagonal boom arm and fixing hub L = 3 + 3 m. Telescopic octagonal boom arm and fixing hub L = 4 + 3 m.
  • Página 34 HANGING SUPPORT FORK TYPE SUPPORT THREE RELAY EQUIPPED OPTIONAL CARD FOR BOX LIGHT OR ELECTROMAGNET AND TRAFFIC LIGHT CONTROL code ACQ9081 METALLIC MASS DETECTOR to open with vehicles 1 channel - 230 Vac code ACG9060 1 channel - 12÷24 Vac/dc code ACG9063 2 channels - 12÷24 Vac/dc code ACG9064...
  • Página 35: Technische Daten

    ANLAGEN LAY-OUT NORMAL Schranke - Photozellen - Verzinkte Metallsäule als Photozellenträger - Fotokontaktleiste - Magnetschleife - Schlüsselschalter - Antenne Abmessungen in mm - Notschalter TECHNISCHE DATEN TECHNISCHE NORMAL EIGENSCHAFTEN Selbsthemmender, auf beiden Seiten montierbarer Getriebemotor zum Antrieb von Schrankenbäumen Max. Baumlänge mit Länge bis zu 6-7 m.
  • Página 36 INSTALLATION NORMAL MONTAGE DER NORMAL-EINHEIT Komponenten zur Installation nach der Norm EN1253 Nach der Zementeinbettung des Sockels in einer geeigneten Position die Normal-Einheit mit ANWENDUNG DER SCHLIESSUNG den gelieferten Muttern und einem Sechskanteinsteckschlüssel Nr. 19 befestigen. Fachpersonen STEUERUNGSSYSTEM Danach den Schrankenbaum in vier Schritten montieren: Fachpersonen Grenzlose (außer einem...
  • Página 37 EINSTELLUNG DER AUSGLEICHSFEDER Die Schranke wird mit bereits eingestellten Ausgleichsfedern geliefert. Werden dem Schrankenbaum zusätzliche Gewichte angesetzt (z.B. pneumatische- oder Fotokontaktleisten), muß er neu ausgewuchtet werden. Wenn der Schrankenbaum dazu neigt, sich zu schnell zu senken, muß auf die Ausgleichsfedern eingewirkt werden.
  • Página 38: Elektroanschlüsse

    ELEKTROANSCHLÜSSE PARK CRX Kode AC07063 KONDENSATOR MOTOR BLINKER SPEISUNG 230Vac 50 Hz ANTENNE BEFLECHTUNG SCHRITT BEI SCHRITT BUZZER ANTENNE R=2K2 STOP SCHLIESSE ÖFFNE 1 ÖFFNE 2 OK SCHLIESSE 12 Vdc max 0,5A für ZUBEHÖRE 12 Vdc max 0,5A für AUTOTEST FÜR GELENKRIPPE RIPPE FOTOZEL.
  • Página 39 A - VERBINDUNGEN Stromversorgung 230Vac 50/60Hz (120V/60Hz auf Anfrage) Gemeinsame Erdungseinheit der Kontakte Kontakt des Endschalters, der die Schließung stoppt (NC) Kontakt des Endschalters, der die Öffnung stoppt (NC) LSSC Nicht benutzt LSSO Nicht benutzt Kontakt Fahrzeuganwesenheits-Anzeige (NO) (nur bei PARK-Modus) PHOT.
  • Página 40 DIP 10 - Funktionsweise nach Stromausfall 4 - Die Zeit für die Programmierung der Codes verlängert sich automatisch, damit - Die Schranke wird geschlossen, wenn nicht vollständig geschlossen anschließend die Fernsteuerung gespeichert werden kann. - Die Schranke bleibt an dem Punkt stehen, an dem der Stromausfall stattfand 5 - Um die Programmierung abzuschließen, 10 sec.
  • Página 41 STANDARDBETRIEB ANTENNE Schranke. Wenn diese Taste während DIP 6 OFF einer Schließbewegung betätigt wird, SCHRITT BEI SCHRITT BEFLECHTUNG BUZZER führt dies zur erneuten Öffnung der EINFAHRT R=2K2 ANTENNE STOP Schranke. SCHLIESSE FERNSTEUERUNG ÖFFNE 1 DIP4 - OFF => Führt einen Befehl der Steuerreihe Öffnen - Stopp - Schließen - Stopp - Öffnen usw.
  • Página 42: Technische Eigenschaften

    ARBEIT IM MANNSBEISEIN IM FALL EINES AUSFALLS DER SICHERHEITEN FUNKTIONSWEISE NACH STROMAUSFALL Wenn die Kontaktleiste ist defekt oder diese arbeit länger als 5 Sekunden, oder wenn die Mit DIP 10 - OFF => Ohne Stromversorgung bleibt die Schranke geschlossen bzw. wird Fotozelle defekt ist oder für mehr als 60 Sekunden arbeit, die Befehle ÖFFNEN 1, ÖFFNEN geschlossen, falls die Schranke gerade dabei war, eine Öffnungs- 2, SCHLIESSEN, und K BUTTON im Mannsbeisein arbeiten.
  • Página 43 OPTIONEN Für die Anschlüsse und die technischen Daten der Zubehöre verweisen wir auf die entsprechenden Betriebsanleitungen. TELESKOPISCHE ACHTECK-STANGE 6 m TELESKOPISCHE ACHTECK-STANGE 7 m Teleskopische Achteck-Stange 6 m mit Nabe L = 3 + 3 m. Teleskopische Achteck-Stange 7 m mit Nabe L = 4 + 3 m. Kode ACG8513 Kode ACG8514 HÄNGEGITTER...
  • Página 44 STÜTZPENDEL ABSTÜTZ TRÄGER FAKULTATIVE PLATINE MIT 3 RELAIS FÜR LICHT BOX ODER ELEKTROMAGNET UND BETRIEBSAMPELANLAGE Kode ACQ9081 MAGNETWINDUNGSSENSOR Für Öffnung mit Fahrzeugen Einkanalig - 230 Vac Kode ACG9060 Einkanalig - 12÷24 Vac/dc Kode ACG9063 Zweikanalig - 12÷24 Vac/dc Kode ACG9064 Hänge Stütze mit Regulierung der Höhe Gabelförmiger Abstützträger, nutzbar für Achteck-Stangen.
  • Página 45: Disposiciòn De La Instalaciòn

    DISPOSICIÒN DE LA INSTALACIÒN Barrera NORMAL - Fotocélulas de seguridad - Pilar galvanizado soporte fotocélula - Fotonervadura - Sensor magnético - Selector con llave - Antena de radio Medidas en mm - Pulsador de urgencia CARACTERÍSTICAS TÉCNICAS CARACTERÍSTICAS NORMAL TÉCNICAS Motorreductor irreversible ambidiestro, utilizado para mover astas de hasta 6-7 m de longitud.
  • Página 46: Montaje De Normal

    INSTALACIÓN NORMAL MONTAJE DE NORMAL Componentes a instalar según la norma EN12453 Una vez cementada la base en la posición elegida, fijar a ella la barrera NORMAL con las USO DEL CIERRE tuercas respectivas, utilizando una llave hexagonal Nº 19. TIPO DE MANDO Personas expertas (fuera Personas expertas...
  • Página 47: Regulación De Los Resortes De Equilibrio

    REGULACIÓN DE LOS RESORTES DE EQUILIBRIO Normalmente, la barrera se entrega con los resortes de equilibrio yá regulados. Si se añade algún peso al asta (ej., bandas neumáticas o fotoeléctricas), es necesario volverlo a equilibrar. Si la asta tira a caer durante el movimiento de bajada, arreglar los resortes de la siguiente manera: Para ello, subir la asta de modo eléctrico o manual hasta la posición vertical y efectúe la regulación con una llave hexagonal Nº...
  • Página 48 CONEXIONES ELÉCTRICAS PARK CRX code AC07063 CONDENSADOR MOTOR INTERMITENTE ALIMENTACION 230Vac 50 Hz ANTENA MASA PASSO PASSO BUZZER ANTENA R=2K2 STOP CIERRA ABRE 1 ABRE 2 OK CIERRA 12 Vdc max 0,5A para ACCESSORIOS 12 Vdc max 0,5A para AUTOTEST PARA COSTA COSTAS FOTOCEL.
  • Página 49: Microinterruptor De Gestión

    A - CONEXIÓN Alimentación 230 Vac 50/60 Hz (120V/60Hz bajo solicitud) Común de los contactos Contacto final de carrera que detiene el cierre (NC) Contacto final de carrera que detiene la abertura (NC) LSSC No utilizados LSSO No utilizados Contacto señalización presencia de vehículo (NO) (solo en modo PARK) PHOT.
  • Página 50: C - Control Del Sentido De Rotación Del Motor

    - la tecla ABERTURA 2 está habilitada solo cuando no hay ningún vehículo sobre el 3 - Pulsar la tecla del mando a distancia (normalmente el canal A) dentro de los 10 segundos sensor magnético conectado al TLC (Traffic Light Control) configurados.
  • Página 51 de abertura no tiene efecto. Si se lo ANTENA MODALIDAD NORMAL acciona con la barra abierta, la cierra. DIP 6 OFF Si se lo acciona durante el movimiento PASSO PASSO MASA BUZZER ENTRADA de cierre, la vuelve a abrir. R=2K2 ANTENA STOP CIERRA...
  • Página 52: Indicador De Señalización Barrera Abierta (Com-Signal)

    la presencia de un vehículo permite la abertura de la barra en modo PARK a través del que relampaguea. mando abertura 1. En este funciòn, será aconsentido el apertura y el cierre solo manteniendo apretados los pulsadores de comandos. El comando radio y el cierre automatico seràn excludidos porque FUNCIONAMIENTO LUEGO DE UN BLACK OUT estas formas de funcionamientos no son permitidas por las normas.
  • Página 53 OPCIONALES Para las conexiones y datos técnicos de los accesorios, consultar los manuales respectivos. BARRA 6 m OCTAGONAL TELESCÓPICA BARRA 7 m OCTAGONAL TELESCÓPICA Barra 6 m octagonal telescópica con cubo L = 3 + 3 m. Barra 7 m octagonal telescópica con cubo L = 4 + 3 m. cód.
  • Página 54: Tarjeta Opcional Con 3 Relés Para Luz Box O Electroimány Gestión Semáforo

    VARILLA PÉNDULO VARILLA DE SOPORTE TARJETA OPCIONAL CON 3 RELÉS PARA LUZ BOX O ELECTROIMÁN Y GESTIÓN SEMÁFORO cód. ACQ9081 SENSOR EN ESPIRAL MAGNÉTICA Para la apertura con vehículos monocanal - 230 Vac cód. ACG9060 monocanal - 12÷24 Vac/dc cód. ACG9063 bicanal - 12÷24 Vac/dc cód.
  • Página 55 NOTES...
  • Página 56 NOTES...
  • Página 57: Assistenza Tecnica

    REGISTRO DI MANUTENZIONE - DOSSIER D’ENTRETIEN - MAINTENANCE LOG WARTUNGSREGISTER - REGISTRO DE MANTENIMIENTO Il presente registro di manutenzione contiene i riferimenti tecnici e le registrazioni delle attività di installazione, manutenzione, riparazione e modifica svolte, e dovrà essere reso disponibile per eventuali ispezioni da parte di organismi autorizzati. Ce dossier d’entretien contient les références techniques et les enregistrements des opérations d’installation, d’entretien, de réparation et de modification effectuées, et devra être rendu disponible pour les inspections éventuelles de part d’orgenismes autorisée.
  • Página 58 ® R.I.B. S.r.l. AZIENDA CON SISTEMA 25014 Castenedolo - Brescia - Italy DI QUALITÀ CERTIFICATO Via Matteotti, 162 DA DNV Tel. ++39.030.2135811 Fax ++39.030.21358279 - 21358278 COMPANY WITH QUALITY SYSTEM CERTIFIED www.ribind.it - ribind@ribind.it automatismi per cancelli BY DNV automatic entry systems DICHIARAZIONE DI CONFORMITÁ...
  • Página 59 CCA1007 CVA1025 CME3067 CME1011 CVA1141 CME5272 CTC1101 CVA1023 CME5028 CME5205 CME1079 CME3029 CTC1101 CTC1124 CME3054 CME8058 CME8068 DSB10X90 CEL1354 CME6017 CCU6207 CCA1050 CME4062 CTC1218 CCA1042G CCA1041G CCA1169G CME5173 CTC1093 CCU6303 CME1059 CPL1019 CME1999 CMO1219 CTC1126 CVA1029 CCU6207 CME8999 CEL1379 CEL1384 CTC1087 CME5051 CME4041...
  • Página 60 NORMAL DUO CARD ACG8010 PER IL COMANDO CONTEMPORANEO DI DUE BARRIERE POUR LA COMMANDE SIMULTANÉE DE DEUX BARRIÈRES FOR CONNECTING TWO BARRIERS AT THE SAME TIME FÜR DIE GLEICHZEITIGE BETÄTIGUNG VON ZWEI SCHRANKEN PARA EL MANDO CONTEMPORÁNEO DE DOS BARRERAS OPEN 1 CLOSE CONTACT RADIO...

Este manual también es adecuado para: