Installation

4.4 Installing the ventilation system

4.4.1 Installation LS300

To install the ventilation grilles, cut two rectan-
gles width b = 490 mm, height a 249 mm,
in the outer wall of the vehicle (for position of
the cuts, see Fig. 14).
1
Cut two rectangles in the
exterior wall of the vehi-
cle.
2
Seal the mounting frame
making it waterproof
( does not apply for
mounting frames with
integral seal) and screw
into position.
3
Insert ventilation grille.
4
Install locking slider.
5
Lock ventilation grille.
b
a
Fig. 15
14 x
Fig. 16
Fig. 17
Fig. 18
Fig. 19
4.4.2 Installing roof exhaust R 500
Measurements of roof exhaust R 500
Length
Width
595 mm
205 mm
Roof cut out:
87mm X 507 mm
1
Seal the installation
bays and screw them
to the vehicle roof.
2
Place the hood in
postion and screw it
to the installation
bays.
14
Height
150 mm
Fig. 20
Fig. 21
Fig. 22