e) Appliance test conditions (TEST): Star Pir goes into TEST by pressing the LED button. The test state lasts 3 minutes and
via LED displays all detections, annulling the block after a first alarm. Attention! The appliance remains permanently in TEST
when it is open.
f) Supervision: Star Pir transmits an operating status signal about every 40 minutes, which is managed by the SILENTRON
supervised control panels - see "supervision function" of the control panel used.
g) Batteries flat signal: the appliance signals via radio to the control panel and locally using 5 beeps that the batteries must be
replaced.
3. START-UP - respect the sequence of the operations
a) Programming the appliance on the control panel or receiver (also see the instructions of the control panel/receiver
used):
•
Open the appliance by loosening the screws on the bottom and open the battery compartment.
•
Place the control panel in PROGRAMMING mode, on the desired zone
•
Extract the battery isolating film, powering the appliance: programming will be confirmed by a Beep from the control panel.
•
Terminate the procedure by assigning the name to the detector (written label and vocal on the control panels). Close the
battery compartment.
b) Positioning:
Determine the position and the height of installation of the appliance depending on the protected area that is to be obtained (see
figure). Use the swivel for corner installation, fastening it to the sliding bracket supplied with the appliance, in a way to allow
extraction. If in doubt regarding the definitive position, it is recommended to fix the appliance temporarily and make the
adjustments and relative detection tests before fixing definitively.
Attention: using the swivel means loosing part of the anti-removal protection. The magnet can be positioned on the bracket, but
is not joined to the wall. If the magnet is not used, the protection must be excluded by placing dip-switch 5 in the ON position.
c) Adjustments (see diagram)
To check the adjustments place the device in TEST state and look at led indications: the red LED indicates the alarm
transmission. The detection tests can be performed with the appliance open.
•
Adjust the PIR sensitivity (dip-switch 1-2), with impulse count on 1 (dip-switch 3 off), limiting the protected area to the
minimum necessary.
•
Check the protected area via the LED, making movements in the same: for a precise definition of the intervention area it is
recommended to turn around agitating the arms instead of advancing/retracting/transversing. If necessary, reduce or
increase the range, repeating the previous tests.
•
When the protected area has been defined, take the PIR impulse count to 2 (dip-switch 3 ON) in order to reduce the
possibility of improper alarm.
d) LED exclusion: for safety reasons and to prevent over-consumption of the appliance the LED must be excluded at the end
of the tests, taking dip-switch 4 to ON. They function anyhow in the test state. Any functioning controls of the detector can be
performed using the control panel TEST functions and/or receiver indicators.
e) Anti-removal: in the case of corner fixing, the magnet must be positioned correctly, joined to the support wall. If this is
missing, the magnet can be positioned in the relevant compartment of the sliding bracket, loosing the anti-removal protection if
this is not joined to the fixture wall.
f) Temperature compensation: the function consists in the automatic increases of the PIR sensitivity when the temperature in
the appliance exceeds 30°C and this is activated by placing dip-switch 6 in ON. Do not active the function unless strictly
necessary.
TECHNICAL FEATURES (see diagrams also)
Power supply: 4.5V via 3 AA 1.5V 2.2Ah batteries - Absorption 70uA at rest, 40mA in transmission – Autonomy of about 2
years, which can be greatly reduced in the case of a busy area and with LED active during normal functioning (dip-switch 4).
Functions: indication of movement in the protected area (intruder alarm) – tampering – supervision – flat batteries.
Radio transmissions: coded at 64 bit in simultaneous Dualband frequency – frequencies and power in compliance with the
law. Range of about 100 m in free space and without interference on the bands.