EN
DESCRIPTION
Compressed air operated piston-type reciprocating pump. This high flow capacity pump is compatible with mineral and synthetic grease and
suitable for large installations with long lengths of piping supplying several outlets simultaneously. This pump is mounted directly on 20 kg, 50
kg and 185 kg drums.
WARNINGS
WARNING: Read all instruction manuals, tags, and labels before
!
operating the equipment. This equipment is for professional use only.
• The use of non compatible fluids may cause damage in the pump and
serious personal injury. This equipment is not intended for use with
fluids that fall within the Group 1 fluid as defined that are explosive,
extremely flammable, highly flammable, flammable, very toxic, toxic,
oxidizing or where the vapor pressure if greater than 7 psi (0,5 bar)
above the pressure atmospheric at the maximum allowable temperature.
• The pump generates high or very high pressures. Do not exceed the
maximum air inlet pressure of 145 psi (10 bar).
• A direct hit against the human body may result in an injury.
INSTALLATION
It is recommended to install this pump on a drum using the bundled
bung adapter (410 001) with a suitable drum cover (418006 for 408
lb drum, 418 004 for 110 lb drum and 418 002 for 44 lb drum). Fasten
the cover onto the drum and screw the nut of the bung adaptor
securely into the 2" bung opening of the cover. Insert the pump
through the nut and adjust it with the star nut to the desired height
(see figure 2).
It is also possible mounting the pump directly fastened on a flat
surface, using the 4 threaded holes (M8) disposed in a ∅3,5" pattern in
the fluid outlet body.
TYPICAL INSTALLATION
Figure 3 is a typical installation shown with all the recommended
accessories for the pump to operate correctly.
NOTE: The compressed air supply must be set between 29 and 145 psi
(2 and 10 bar), being 90 psi (6 bar) the recommended pressure. An air
closing valve must be installed, in order to be able to close the
compressed air line at the end of the day (If the air inlet not is closed
and there is a leakage in some point of the grease outlet circuit, the
pump will start automatically, emptying the container).
Pos
Description
A
Air shut off valve
B
Filter regulator
C
Air hose
D
Quick coupling
E
Connection nipple
F
Pump (185 kg drum)
G
Grease hose
H
Grease shut off valve
I
Cover
J
Follower plate
K
Pressure Relief Valve
2
853 827 R. 07/17
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533
Part No.
950319+239004
241001
247710
251438
255338
530610
945676+841700+945557
950304
418006
417004
• This unit may have stored pressure, release all pressure and disconnect
from any fluid systems before servicing. To ensure safe operation of this
unit, all service work should be by qualified personnel only.
• When not in use, be sure to shut off the air supply to avoid accidents.
• Do not alter or modify this equipment. Use only SAMSON genuine
components. Any unauthorized tampering with this equipment,
improper use, poor maintenance or removal of identification labels may
invalidate the guarantee.
• All fittings in the system connected to the outlet of the pump should be
suitable for the maximum possible pressure generated by the pump/air
motor. If the systems cannot be designed to take the maximum pressure
produced by the pump, safety valves or diverter valves should be fitted.
418 006
418 004
418 002
K
410 001
Fig. 2
Fig. 3