SAFETY INFORMATION
WARNING: Do not exceed 40 watts per bulb. Use of higher-rated bulbs may result in
a fire, causing property damage or personal injury.
WARNING: Make sure the power is turned off before proceeding. Only a licensed
electrician should perform any electrical repairs or rewiring of this unit in
accordance with national and local codes.
Follow the original wire routing, color coding and securing locations when making
repairs or replacements to any electrical component."
WARNING: Electrical outlet wiring must comply with local building codes and
other applicable regulations to reduce the risk of fire, electrical shock and injury
to persons.
WARNING: Do not use this fireplace if any part of it has been under water.
Immediately call a qualified service technician to inspect the fireplace and
replace any part of the electrical system.
WARNING: Disconnect power before attempting any maintenance or cleaning
to reduce the risk of fire, electrical shock or personal injury.
WARNING
To avoid injury from unexpected starting or electrical shock, do not plug the power cord into a
source of power during unpacking and assembly. The cord must remain unplugged whenever
you are adjusting/assembling the fireplace.
If any part is missing or damaged, do not attempt to use or plug in the power cord until the missing
or damaged part is correctly replaced. To avoid electric shock, use only identical replacement parts
when servicing double-insulated tools.
Cold climate installation recommendation: When installing this unit against a non-insulated
exterior wall or chase, the outer walls must be insulated to conform to applicable insulation
codes.

ELECTRICAL CONNECTION

A 15 AMP, 120 V, 60 Hz circuit with a properly grounded outlet is required. Preferably, the fire-
place will be on a dedicated circuit as other appliances on the same circuit may cause the circuit
breaker to trip or the fuse to blow when the heater is in operation. The unit comes standard with 6
ft. (1828 mm) three prong cord, exiting from the rear of the fireplace. Plan the installation to avoid
the use of an extension cord. If an extension cord must be used, it must be a minimum 14 AWG,
three wire with grounding type plug connector and rated not less than 1,875 watts. The cord shall
not be more than 20 ft. in length.
4