GROUNDING INSTRUCTIONS

This machine must be grounded. If it should malfunction or
break down, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock. This
machine is equipped with a cord having an equipment-
grounding conductor and grounding plug. The plug must be
inserted into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the
equipment-grounding conductor
can result in a risk of electric
shock.
electrician or service person if
you are in doubt as to whether
the outlet is properly grounded.
Do not modify the plug provided
with the machine. If it will not fi t
the outlet, have a proper outlet
installed by a qualifi ed electrician.
This machine is for use on a nominal 120-volt circuit, and has
a grounded plug that looks like the plug illustrated in fi gure A.
Make sure you have the correct voltage and frequency
before connecting the power cord to an outlet. A tempo-
rary adapter that looks like the adapter illustrated in fi gures B
and C may be used to connect this plug to a 2-pole receptacle
as shown in fi gure B if a properly outlet is not available. The
temporary adapter should be used only until a properly ground-
ed outlet (fi gure A) can be installed by a qualifi ed electrician.
The green colored rigid car, lug, or the like extending from the
adapter must be connected to a permanent ground such as a
properly grounded outlet box cover. Whenever the adapter is
used, it must be held in place by a metal screw.
NOTE: In Canada, the use of a temporary adapter is not
permitted the Canadian Electrical Code.
WARNING: To prevent possible electric
shock, protect the machine from
rain. Keep the machine in a dry
building.
WARNING: For maximum protection against
electrical shock,
that is protected by a ground fault
circuit interrupter. Consult your
electrical contractor.
WARNING: Have worn, cut or damaged cords
replaced by an authorized service
person.

EXTENSION CORDS

Use only three-wire 14/3 AWG (AWG means American Wire
Gauge) or larger gauge approved extension cords that have
three-prong grounding type plugs and three-pole receptacles
that accept the appliance's plug.
damaged cords or plugs. When servicing, refer to authorized
person only. Use only identical replacement parts.
WARNING: If you use an extension cord, use
an extension cord with minimum
wire size 14 AWG. Do not use an
extension cord longer than
feet. Do not join two extension
cords.
WARNING: Do not move the machine
an electrical cord. Always lift the
cord over the machine.
-4- FORM NO. 70796A
Check with a qualifi ed
use a circuit
Replace or repair any
50
over
Figure A
Grounding
Pin
Cover of Grounded
Outlet Box
Figure B
Metal
Screw
Cover of
Grounded
Outlet Box
NOTE: Do not use adapters shown in fi gure B & C in Canada
Clarke
®
Operator's Manual (EN) - Carpet Master 30
Figure C
Grounding
Means