7
SAFETY STANDARDS
This operating manual:
- is valid for compressors-suction pumps with side channel generally identified by the term "blowers", TMD Atex version of series K-MS
GOR, category II 2G, suitable for conveying biogas and flammable gases;
- contains instructions for transport, installation, putting into service, operation, storage and maintenance of the compressors / suction
pumps with side channel,
- must be read carefully and understood well before doing anything with the unit;
- must be followed meticulously;
- must be kept constantly within reach in the location where the unit is used.
Failure to observe the safety rules may cause serious injury to persons - and possibly death - in addition to damage to property and the
environment.
The Atex version of the TMD blower with side channel consists of the parts shown below:
Silencer
Electrical Motor
Housing
Base
7.1
NOTES FOR THE USER AND FOR SAFETY
The safety rules in this user manual are marked by a danger symbol. An explanation of the danger can be found to the side of this
symbol. Please follow the procedures described meticulously to avoid danger to persons and property!
This is a generic and specific DANGER symbol that indicates dangers that may cause personal injury with deadly
or serious consequences if the necessary precautions are not taken.
These are PROHIBITION symbols that indicate operations that must not be performed as they may cause personal
injury with deadly or serious consequences.
The term WARNING! is used to provide the user with further information and, in particular, to point out dangers that
WARNING!
may cause material damage.
NOTES FOR
The NOTES are used to provide the user with information that ensures the best possible use of the unit, with better
performance, in a safe and environmentally friendly way.
THE USER
7.2
GENERAL SAFETY WARNINGS
The 'SCL K' compressors-suction pumps are group II units for use in classified zones and were designed and built in compliance with
the Directive ATEX 94/9/EC, according to European standards EN 1127-1, EN 13463-1 and EN 13463-5.
The 'SCL R-MD' compressor-suction pumps have been designed and built for industrial applications and to be installed and used by
qualified personnel in classified environments against the risk of explosion due to the presence of gas and/or dust and generally as units
which are to be incorporated into a machine or plant.
Installation, connection, start up and maintenance must be done exclusively by qualified personnel who must bear the following points in
mind:
-
the classification of the zone and/or plant in which the machine is to be installed
ENERGOEKONOM spol. s r.o., Wolkerova 433, CZ-250 82 Úvaly, Czech Republic, Tel.: +420 281 981 055, info@energoekonom.cz, www.energoekonom.cz
Mechanical Seal
26 / 96
Manifolds
Oil reservoir
Bearing box
Casing
Body